Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jul;9(4):286-90.

Diagnostic value of immunoperoxidase staining and immunofluorescence in the study of kidney biopsy specimens

Affiliations
  • PMID: 26174455
Free article
Comparative Study

Diagnostic value of immunoperoxidase staining and immunofluorescence in the study of kidney biopsy specimens

Mohammad Jafari et al. Iran J Kidney Dis. 2015 Jul.
Free article

Abstract

Introduction: This study aimed to determine diagnostic value of immunoperoxidase in comparison with immunofluorescence in the diagnostic assessment of kidney biopsy specimens.

Materials and methods: Forty-eight kidney biopsy specimens were used to compare a direct immunofluorescence technique with immunoperoxidase techniques on paraffin sections. The sensitivity and specificity were calculated. The kappa statistic for agreement between the two tests was categorized as poor (zero to 0.2), moderate (0.21 to 0.45), good (0.46 to 0.75), and almost perfect concordance (0.76 to 1.0).

Results: Compared with immunofluorescence, the immunoperoxidase technique presented a sensitivity of 88.55% and a specificity of 69.22%. Its sensitivity in the staining for IgG, IgM, and IgA was 93.75%, 95.45%, and 76.47%, respectively. The specificity of this test in the staining for IgG, IgM, and IgA was 54.54%, 57.14%, and 96.00%, respectively. The overall kappa value was 0.60 and it was 0.60 for assessing staining intensity. There was a moderate agreement between immunoperoxidase and immunofluorescence in the positive or negative staining for IgG and IgM, as well as a good agreement in the positive or negative staining for IgA. For the staining intensity, the two tests had a good concordance for IgG and IgA and a moderate concordance for IgM.

Conclusions: Although immunoperoxidase method has a lower overall diagnostic performance as compared to immunofluorescence, given the good concordance between the two techniques, it can be an alternative method for immunofluorescence study of kidney biopsy specimens, particularly where immunofluorescence fails or is not available.

PubMed Disclaimer

Publication types

LinkOut - more resources