. 2016 Aug;30(4):467-73.
doi: 10.1007/s10877-015-9739-y. Epub 2015 Jul 16.

A mainstream monitoring system for respiratory CO2 concentration and gasflow

Affiliations

A mainstream monitoring system for respiratory CO2 concentration and gasflow

Jiachen Yang et al. J Clin Monit Comput. 2016 Aug.

Abstract

Continuous respiratory gas monitoring is an important tool for clinical monitoring. In particular, measurement of respiratory [Formula: see text] concentration and gasflow can reflect the status of a patient by providing parameters such as volume of carbon dioxide, end-tidal [Formula: see text] respiratory rate and alveolar deadspace. However, in the majority of previous work, [Formula: see text] concentration and gasflow have been studied separately. This study focuses on a mainstream system which simultaneously measures respiratory [Formula: see text] concentration and gasflow at the same location, allowing for volumetric capnography to be implemented. A non-dispersive infrared monitor is used to measure [Formula: see text] concentration and a differential pressure sensor is used to measure gasflow. In developing this new device, we designed a custom airway adapter which can be placed in line with the breathing circuit and accurately monitor relevant respiratory parameters. Because the airway adapter is used both for capnography and gasflow, our system reduces mechanical deadspace. The finite element method was used to design the airway adapter which can provide a strong differential pressure while reducing airway resistance. Statistical analysis using the coefficient of variation was performed to find the optimal driving voltage of the pressure transducer. Calibration between variations and flows was used to avoid pressure signal drift. We carried out targeted experiments using the proposed device and confirmed that the device can produce stable signals.

Keywords: Capnography; Differential pressure; FEM; Gasflow; NDIR; Respiratory gas monitoring.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Am J Emerg Med. 2012 Feb;30(2):358-61 - PubMed
    1. Respir Care. 2013 Jul;58(7):1152-6 - PubMed
    1. Appl Opt. 2013 May 1;52(13):3027-30 - PubMed
    1. J Clin Monit Comput. 2014 Aug;28(4):363-9 - PubMed
    1. Crit Care Nurse. 2003 Aug;23(4):83-8 - PubMed

MeSH terms

LinkOut - more resources