Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Jan;24(1):10-21.

Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves

  • PMID: 26182615
Comparative Study

Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves

Barbara E Stähli et al. J Heart Valve Dis. 2015 Jan.

Abstract

Background and aim of the study: The study aim was to investigate prosthesis-specific predictors for paravalvular aortic regurgitation (PAR) in self-expandable versus balloon-expandable transcatheter heart valves (THVs). PAR is frequently observed after transcatheter aortic valve replacement (TAVR). As self-expandable and balloon-expandable THVs engage differently with the native aortic valve structures, factors that impact PAR may differ between the prosthesis types.

Methods: A total of 137 TAVR patients who underwent pre-procedural multidetector computed tomography and post-procedural transthoracic echocardiography were studied. Predictors for PAR, including annulus area oversizing and aortic valve calcification mass and volume, were analyzed in a multivariate model.

Results: The Medtronic CoreValve (MCV) prosthesis was utilized in 68 patients (50%), and the Edwards SAPIEN (ES) prosthesis in 69 (50%). More than mild PAR was observed in 43 patients (32%). Among MCV patients, aortic valve calcification volume and mass were higher in those with more than mild PAR than in those with none or mild PAR (p = 0.04, p = 0.03, respectively). Among ES patients, the annulus area and perimeter oversizing were lower in those with more than mild PAR compared to those with no or mild PAR (p = 0.001). By univariate and multivariate logistic regression analysis, aortic valve calcification mass was the only independent predictor for PAR in MCV patients (p = 0.02), whereas in ES patients it was THV undersizing (p = 0.002), irrespective of the calcific burden.

Conclusion: For self-expandable THVs, aortic valve calcification mass was the strongest predictor of PAR, whereas for balloon-expandable THVs it was prosthesis undersizing. Hence, in patients evaluated for TAVR these parameters should guide the selection of prosthesis type.

PubMed Disclaimer

Publication types

MeSH terms

Supplementary concepts

LinkOut - more resources