Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Nov;117(2):358-63.
doi: 10.1016/j.radonc.2015.07.006. Epub 2015 Jul 18.

Split dose carbon ion irradiation of the rat spinal cord: Dependence of the relative biological effectiveness on dose and linear energy transfer

Affiliations

Split dose carbon ion irradiation of the rat spinal cord: Dependence of the relative biological effectiveness on dose and linear energy transfer

Maria Saager et al. Radiother Oncol. 2015 Nov.

Abstract

Purpose: To measure the relative biological effectiveness (RBE) of carbon ions relative to 15 MeV photons in the rat spinal cord for different linear energy transfers (LET) to validate model calculations.

Methods and materials: The cervical spinal cord of rats was irradiated with 2 fractions of carbon ions at six positions of a 6 cm spread-out Bragg-peak (SOBP, 16-99 keV/μm). TD50-values (dose at 50% complication probability) were determined from dose-response curves for the endpoint radiation induced myelopathy (paresis grade II) within 300 days after irradiation. Using previously published TD50-values for photons (Karger et al., 2006; Debus et al., 2003), RBE-values were determined and compared with predictions of two versions of the local effect model (LEM I and IV).

Results: TD50-values for paresis grade II were 26.7 ± 0.4 Gy (16 keV/μm), 24.0 ± 0.3 Gy (21 keV/μm), 22.5 ± 0.3 Gy (36 keV/μm), 20.1 ± 1.2 Gy (45 keV/μm), 17.7 ± 0.3 Gy (66 keV/μm), and 14.9 ± 0.3 Gy (99 keV/μm). RBE-values increased from 1.28 ± 0.03 (16 keV/μm) up to 2.30 ± 0.06 at 99 keV/μm. At the applied high fractional doses, LEM I fits best at 16 keV/μm and deviates progressively toward higher LETs while LEM IV agrees best at 99 keV/μm and shows increasing deviations, especially below 66 keV/μm.

Conclusions: The measured data improve the knowledge on the accuracy of RBE-calculations for carbon ions.

Keywords: Carbon ion radiotherapy; Dose response; Linear energy transfer (LET); Relative biological effectiveness (RBE).

PubMed Disclaimer

Publication types

LinkOut - more resources