(18)F-NaF PET/CT: EANM procedure guidelines for bone imaging
- PMID: 26201825
- DOI: 10.1007/s00259-015-3138-y
(18)F-NaF PET/CT: EANM procedure guidelines for bone imaging
Erratum in
-
Correction to: 18F-NaF PET/CT: EANM procedure guidelines for bone imaging.Eur J Nucl Med Mol Imaging. 2018 Feb;45(2):322. doi: 10.1007/s00259-017-3874-2. Eur J Nucl Med Mol Imaging. 2018. PMID: 29130115
Abstract
The aim of this guideline is to provide minimum standards for the performance and interpretation of (18)F-NaF PET/CT scans. Standard acquisition and interpretation of nuclear imaging modalities will help to provide consistent data acquisition and numeric values between different platforms and institutes and to promote the use of PET/CT modality as an established diagnostic modality in routine clinical practice. This will also improve the value of scientific work and its contribution to evidence-based medicine.