State of the Art: Iterative CT Reconstruction Techniques
Abstract
Owing to recent advances in computing power, iterative reconstruction (IR) algorithms have become a clinically viable option in computed tomographic (CT) imaging. Substantial evidence is accumulating about the advantages of IR algorithms over established analytical methods, such as filtered back projection. IR improves image quality through cyclic image processing. Although all available solutions share the common mechanism of artifact reduction and/or potential for radiation dose savings, chiefly due to image noise suppression, the magnitude of these effects depends on the specific IR algorithm. In the first section of this contribution, the technical bases of IR are briefly reviewed and the currently available algorithms released by the major CT manufacturers are described. In the second part, the current status of their clinical implementation is surveyed. Regardless of the applied IR algorithm, the available evidence attests to the substantial potential of IR algorithms for overcoming traditional limitations in CT imaging.
(©) RSNA, 2015.
Similar articles
-
Reducing CT radiation dose with iterative reconstruction algorithms: the influence of scan and reconstruction parameters on image quality and CTDIvol.Eur J Radiol. 2014 Sep;83(9):1645-54. doi: 10.1016/j.ejrad.2014.05.033. Epub 2014 Jun 5. Eur J Radiol. 2014. PMID: 25037931
-
Computed tomography radiation dose reduction: effect of different iterative reconstruction algorithms on image quality.J Comput Assist Tomogr. 2014 Nov-Dec;38(6):815-23. doi: 10.1097/RCT.0000000000000128. J Comput Assist Tomogr. 2014. PMID: 24983438
-
Iterative Reconstruction Techniques in Abdominopelvic CT: Technical Concepts and Clinical Implementation.AJR Am J Roentgenol. 2015 Jul;205(1):W19-31. doi: 10.2214/AJR.14.13402. AJR Am J Roentgenol. 2015. PMID: 26102414 Review.
-
Turn down the noise--a blinded evaluation of iterative image reconstruction in radiation therapy computed tomography simulation.Pract Radiat Oncol. 2015 Jul-Aug;5(4):e393-400. doi: 10.1016/j.prro.2014.12.006. Epub 2015 Feb 7. Pract Radiat Oncol. 2015. PMID: 25666989
-
A new era in computed tomographic dose optimization: the impact of iterative reconstruction on image quality and radiation dose.J Comput Assist Tomogr. 2013 Nov-Dec;37(6):924-31. doi: 10.1097/RCT.0b013e318282d95a. J Comput Assist Tomogr. 2013. PMID: 24270114 Review.
Cited by
-
[Noise Reduction Effect of Deep-learning-based Image Reconstruction Algorithms in Thin-section Chest CT].Sichuan Da Xue Xue Bao Yi Xue Ban. 2021 Mar;52(2):286-292. doi: 10.12182/20210360506. Sichuan Da Xue Xue Bao Yi Xue Ban. 2021. PMID: 33829704 Free PMC article. Chinese.
-
Cerebral CTA with Low Tube Voltage and Low Contrast Material Volume for Detection of Intracranial Aneurysms.AJNR Am J Neuroradiol. 2016 Oct;37(10):1774-1780. doi: 10.3174/ajnr.A4803. Epub 2016 May 5. AJNR Am J Neuroradiol. 2016. PMID: 27151751 Free PMC article.
-
Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise.Korean J Radiol. 2021 Jan;22(1):131-138. doi: 10.3348/kjr.2020.0116. Epub 2020 Jul 27. Korean J Radiol. 2021. PMID: 32729277 Free PMC article.
-
Improved image quality in CT pulmonary angiography using deep learning-based image reconstruction.Sci Rep. 2024 Jan 30;14(1):2494. doi: 10.1038/s41598-024-52517-2. Sci Rep. 2024. PMID: 38291105 Free PMC article.
-
Guideline on the use of iodinated contrast media in patients with kidney disease 2018.Jpn J Radiol. 2020 Jan;38(1):3-46. doi: 10.1007/s11604-019-00850-2. Jpn J Radiol. 2020. PMID: 31709498 No abstract available.