Fracturing the Ring of Small Mitroflow Bioprostheses by High-Pressure Balloon Predilatation in Transcatheter Aortic Valve-in-Valve Implantation
- PMID: 26208503
- DOI: 10.1161/CIRCINTERVENTIONS.115.002667
Fracturing the Ring of Small Mitroflow Bioprostheses by High-Pressure Balloon Predilatation in Transcatheter Aortic Valve-in-Valve Implantation
Keywords: aortic valve; bioprosthesis; dilatation; transcatheter aortic valve implantation; transcatheter valve-in-valve implantation.
Similar articles
-
Balloon valuloplasty prior to transcatheter valve-in-valve implantation in a degenerated Mitroflow aortic bioprosthesis.Catheter Cardiovasc Interv. 2013 May;81(6):1075-8. doi: 10.1002/ccd.24540. Epub 2012 Jul 23. Catheter Cardiovasc Interv. 2013. PMID: 22744728
-
First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve.Catheter Cardiovasc Interv. 2013 Dec 1;82(7):E929-31. doi: 10.1002/ccd.24574. Epub 2013 Jul 24. Catheter Cardiovasc Interv. 2013. PMID: 22821872
-
Use of balloon expandable transcatheter valves for valve-in-valve implantation in patients with degenerative stentless aortic bioprostheses: Technical considerations and results.J Thorac Cardiovasc Surg. 2014 Sep;148(3):917-22; discussion 922-4. doi: 10.1016/j.jtcvs.2014.05.029. Epub 2014 May 16. J Thorac Cardiovasc Surg. 2014. PMID: 25037622
-
Which available transapical transcatheter valve fits into degenerated aortic bioprostheses?Interact Cardiovasc Thorac Surg. 2010 Jul;11(1):83-5. doi: 10.1510/icvts.2010.234625. Epub 2010 Apr 15. Interact Cardiovasc Thorac Surg. 2010. PMID: 20395247 Review.
-
Transcatheter aortic valve-in-valve implantation for patients with degenerative surgical bioprosthetic valves.Curr Probl Cardiol. 2014 Jan;39(1):7-27. doi: 10.1016/j.cpcardiol.2013.10.001. Epub 2013 Oct 24. Curr Probl Cardiol. 2014. PMID: 24331437 Review.
Cited by
-
Advancements in Transcatheter Aortic Valve Implantation: A Focused Update.Medicina (Kaunas). 2021 Jul 14;57(7):711. doi: 10.3390/medicina57070711. Medicina (Kaunas). 2021. PMID: 34356992 Free PMC article. Review.
-
Frequency of Bioprosthetic Valve Fracturing Utilization in an All-Comers Valve-in-Valve TAVR Cohort.Front Cardiovasc Med. 2021 Jul 1;8:653871. doi: 10.3389/fcvm.2021.653871. eCollection 2021. Front Cardiovasc Med. 2021. PMID: 34277723 Free PMC article.
-
Bioprosthetic Aortic Valve Fracture During Valve-in-valve Transcatheter Aortic Valve Implantation.Interv Cardiol. 2019 Nov 18;14(3):147-151. doi: 10.15420/icr.2019.08.R2. eCollection 2019 Nov. Interv Cardiol. 2019. PMID: 31867060 Free PMC article. Review.
-
New Insights and Perspective on Bioprosthetic Valve Fracture From Bench Testing and Computed Tomography Analysis.Struct Heart. 2024 Feb 5;8(3):100276. doi: 10.1016/j.shj.2023.100276. eCollection 2024 May. Struct Heart. 2024. PMID: 38799806 Free PMC article.
-
Valve-in-valve transcatheter aortic valve replacement (TAVR) leads to lower device success compared to TAVR in native stenosis.Front Cardiovasc Med. 2025 Apr 22;12:1465409. doi: 10.3389/fcvm.2025.1465409. eCollection 2025. Front Cardiovasc Med. 2025. PMID: 40391383 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources