Ti-6Al-4V triply periodic minimal surface structures for bone implants fabricated via selective laser melting
- PMID: 26210549
- DOI: 10.1016/j.jmbbm.2015.06.024
Ti-6Al-4V triply periodic minimal surface structures for bone implants fabricated via selective laser melting
Abstract
Triply periodic minimal surface (TPMS) structures have already been shown to be a versatile source of biomorphic scaffold designs. Therefore, in this work, Ti-6Al-4V Gyroid and Diamond TPMS lattices having an interconnected high porosity of 80-95% and pore sizes in the range of 560-1600 μm and 480-1450 μm respectively were manufactured by selective laser melting (SLM) for bone implants. The manufacturability, microstructure and mechanical properties of the Ti-6Al-4V TPMS lattices were evaluated. Comparison between 3D micro-CT reconstructed models and original CAD models of the Ti-6Al-4V TPMS lattices shows excellent reproduction of the designs. The as-built Ti-6Al-4V struts exhibit the microstructure of columnar grains filled with very fine and orthogonally oriented α' martensitic laths with the width of 100-300 nm and have the microhardness of 4.01 ± 0.34 GPa. After heat treatment at 680°C for 4h, the α' martensite was converted to a mixture of α and β, in which the α phase being the dominant fraction is present as fine laths with the width of 500-800 nm and separated by a small amount of narrow, interphase regions of dark β phase. Also, the microhardness is decreased to 3.71 ± 0.35 GPa due to the coarsening of the microstructure. The 80-95% porosity TPMS lattices exhibit a comparable porosity with trabecular bone, and the modulus is in the range of 0.12-1.25 GPa and thus can be adjusted to the modulus of trabecular bone. At the same range of porosity of 5-10%, the moduli of cortical bone and of the Ti-6Al-4V TPMS lattices are in a similar range. Therefore, the modulus and porosity of Ti-6Al-4V TPMS lattices can be tailored to the levels of human bones and thus reduce or avoid "stress shielding" and increase longevity of implants. Due to the biomorphic designs, and high interconnected porosity and stiffness comparable to human bones, SLM-made Ti-6Al-4V TPMS lattices can be a promising material for load bearing bone implants.
Keywords: Additive manufacturing; Porous materials; Selective laser melting; Titanium alloys; Triply periodic minimal surface.
Copyright © 2015 Elsevier Ltd. All rights reserved.
Similar articles
-
Microstructural and surface modifications and hydroxyapatite coating of Ti-6Al-4V triply periodic minimal surface lattices fabricated by selective laser melting.Mater Sci Eng C Mater Biol Appl. 2017 Jun 1;75:1515-1524. doi: 10.1016/j.msec.2017.03.066. Epub 2017 Mar 10. Mater Sci Eng C Mater Biol Appl. 2017. PMID: 28415445
-
Ductility improvement due to martensite α' decomposition in porous Ti-6Al-4V parts produced by selective laser melting for orthopedic implants.J Mech Behav Biomed Mater. 2016 Feb;54:149-58. doi: 10.1016/j.jmbbm.2015.09.020. Epub 2015 Sep 28. J Mech Behav Biomed Mater. 2016. PMID: 26458113
-
Properties of a porous Ti-6Al-4V implant with a low stiffness for biomedical application.Proc Inst Mech Eng H. 2009 Feb;223(2):173-8. doi: 10.1243/09544119JEIM466. Proc Inst Mech Eng H. 2009. PMID: 19278194
-
Bio-mechanical analysis of porous Ti-6Al-4V scaffold: a comprehensive review on unit cell structures in orthopaedic application.Biomed Phys Eng Express. 2024 Oct 14;10(6). doi: 10.1088/2057-1976/ad8202. Biomed Phys Eng Express. 2024. PMID: 39353464 Review.
-
Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications.J Mech Behav Biomed Mater. 2009 Jan;2(1):20-32. doi: 10.1016/j.jmbbm.2008.05.004. Epub 2008 May 29. J Mech Behav Biomed Mater. 2009. PMID: 19627804 Review.
Cited by
-
Metal Material, Properties and Design Methods of Porous Biomedical Scaffolds for Additive Manufacturing: A Review.Front Bioeng Biotechnol. 2021 Mar 26;9:641130. doi: 10.3389/fbioe.2021.641130. eCollection 2021. Front Bioeng Biotechnol. 2021. PMID: 33842445 Free PMC article. Review.
-
Design and Fabrication of a Customized Partial Hip Prosthesis Employing CT-Scan Data and Lattice Porous Structures.ACS Omega. 2021 Mar 5;6(10):6902-6913. doi: 10.1021/acsomega.0c06144. eCollection 2021 Mar 16. ACS Omega. 2021. PMID: 33748604 Free PMC article.
-
Osseointegration of titanium scaffolds manufactured by selective laser melting in rabbit femur defect model.J Mater Sci Mater Med. 2019 Feb 12;30(2):26. doi: 10.1007/s10856-019-6227-9. J Mater Sci Mater Med. 2019. PMID: 30747343
-
Mechanical Properties of Optimized Diamond Lattice Structure for Bone Scaffolds Fabricated via Selective Laser Melting.Materials (Basel). 2018 Mar 3;11(3):374. doi: 10.3390/ma11030374. Materials (Basel). 2018. PMID: 29510492 Free PMC article.
-
A Numerical Study of Geometry's Impact on the Thermal and Mechanical Properties of Periodic Surface Structures.Materials (Basel). 2021 Jan 16;14(2):427. doi: 10.3390/ma14020427. Materials (Basel). 2021. PMID: 33467124 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous