Follow up retrospective study of compliance with a standard of care for retinopathy of prematurity in one neonatal intensive care unit
- PMID: 2621548
- DOI: 10.3928/0191-3913-19891101-09
Follow up retrospective study of compliance with a standard of care for retinopathy of prematurity in one neonatal intensive care unit
Abstract
A retrospective chart review was conducted to determine the impact of recently instituted guidelines on compliance with the standard of care for retinopathy of prematurity (ROP) in the Newborn Intensive Care Unit at the University of Utah Medical Center. In a previous study, it was found that infants eligible for participation in a National Institutes of Health-funded study of ROP were routinely receiving screening eye examinations, whereas infants who qualified for ROP screening according to the standard of care, but not eligible for the study, were seen infrequently. Consequently, a plan to improve the compliance with the standard of care for all infants who fit the standard criteria was implemented. The comparison revealed significant improvement in compliance rates. In one subgrouping of infants, compliance rose from three of 16 (18.75%) infants screened for ROP according to the standard of care, to nine of 11 (82%) infants screened for ROP according to the revised standard. This increase in compliance appears to be due to adherence to guidelines recommended in an earlier study, which included increasing staff awareness of the standard of care, designating a person to schedule and track infants who fit the screening criteria, and including the need for ROP screening on the admission and discharge summary.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources