Identification of certain false-positive results in the Cand-Tec test for candidal antigen
- PMID: 2622476
Identification of certain false-positive results in the Cand-Tec test for candidal antigen
Abstract
By repeated testing of sera after heating (56 degrees C, 15 min) certain false-positives in the Cand-Tec test can be identified from the thermo-resistance of the reaction. True titers are drastically reduced by such pretreatment of sera. The thermostable antigen giving rise to falsely positive agglutination is not identical with mannan.
Similar articles
-
A comparison of the specificity and sensitivity of two Candida antigen assay systems for the diagnosis of deep candidiasis in patients with hematologic diseases.Med Sci Monit. 2003 Feb;9(2):MT1-7. Med Sci Monit. 2003. PMID: 12601299
-
[The evaluation of the Cand-Tec latex agglutination test (Ramco) in disseminated candidiasis].Mycoses. 1988 Aug;31(8):433-7. Mycoses. 1988. PMID: 3185611 German. No abstract available.
-
[Predictive potential of positive values in the latex agglutination test for Candida antigen (Cand-Tec)].Schweiz Med Wochenschr. 1988 Jan 16;118(2):42-8. Schweiz Med Wochenschr. 1988. PMID: 3344408 German.
-
[Immunodiagnosis and blood biochemical diagnosis of visceral candidiasis and the cutoff limits of positive].Rinsho Byori. 1996 Jun;44(6):505-11. Rinsho Byori. 1996. PMID: 8752726 Review. Japanese.
-
New developments in the serological diagnosis of Candida infection.Mykosen Suppl. 1988;2:34-8. Mykosen Suppl. 1988. PMID: 3078021 Review. No abstract available.
Cited by
-
Nonvalue of antigen detection immunoassays for diagnosis of candidemia.J Clin Microbiol. 1990 Oct;28(10):2320-6. doi: 10.1128/jcm.28.10.2320-2326.1990. J Clin Microbiol. 1990. PMID: 2229358 Free PMC article.
-
Diagnosis of systemic candidiasis by enzyme immunoassay detection of specific antibodies to mycelial phase cell wall and cytoplasmic candidal antigens.Eur J Clin Microbiol Infect Dis. 1993 Nov;12(11):839-46. doi: 10.1007/BF02000404. Eur J Clin Microbiol Infect Dis. 1993. PMID: 8112354
-
Diagnosis of disseminated candidiasis in hospitalized patients using the Cand-Tec latex agglutination assay.Mycopathologia. 1992 Jun;118(3):153-62. doi: 10.1007/BF00437148. Mycopathologia. 1992. PMID: 1528230
-
Retrospective evaluation of two latex agglutination tests for detection of circulating antigens during invasive candidosis.J Clin Microbiol. 1992 Aug;30(8):2158-64. doi: 10.1128/jcm.30.8.2158-2164.1992. J Clin Microbiol. 1992. PMID: 1500526 Free PMC article.
-
Diagnosis of invasive mycoses in severely immunosuppressed patients.Ann Hematol. 1993 Jul;67(1):1-11. doi: 10.1007/BF01709659. Ann Hematol. 1993. PMID: 8334194 Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical