Metric Development for an Arthroscopic Bankart Procedure: Assessment of Face and Content Validity
- PMID: 26239785
- DOI: 10.1016/j.arthro.2015.04.093
Metric Development for an Arthroscopic Bankart Procedure: Assessment of Face and Content Validity
Abstract
Purpose: To establish the metrics (operational definitions) necessary to characterize a reference arthroscopic Bankart procedure, and to seek consensus from experienced shoulder arthroscopists on the appropriateness of the steps, as well as errors identified.
Methods: Three experienced arthroscopic shoulder surgeons and an experimental psychologist (comprising the Metrics Group) deconstructed an arthroscopic Bankart procedure. Fourteen full-length videos were analyzed to identify the essential steps and potential errors. Sentinel (i.e., more serious) errors were defined as either (1) potentially jeopardizing the procedure outcome or (2) creating iatrogenic damage to the shoulder. The metrics were stress tested for clarity and the ability to be scored in binary fashion during a video review as either occurring or not occurring. The metrics were subjected to analysis by a panel of 27 experienced arthroscopic shoulder surgeons to obtain face and content validity using a modified Delphi Panel methodology (consensus opinion of experienced surgeons rendered by cyclical deliberations).
Results: Forty-five steps and 13 phases characterizing an arthroscopic Bankart procedure were identified. Seventy-seven procedural errors were specified, with 20 designated as sentinel errors. The modified Delphi Panel deliberation created the following changes: 2 metrics were deleted, 1 was added, and 5 were modified. Consensus on the resulting Bankart metrics was obtained and face and content validity verified.
Conclusions: This study confirms that a core group of experienced arthroscopic surgeons is able to perform task deconstruction of an arthroscopic Bankart repair and create unambiguous step and error definitions (metrics) that accurately characterize the essential components of the procedure. Analysis and revision by a larger panel of experienced arthroscopists were able to validate the Bankart metrics.
Clinical relevance: The ability to perform task deconstruction and validate the resulting metrics will play a key role in improving surgical skills training and assessing trainee progression toward proficiency.
Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Arthroscopic Rotator Cuff Repair Metrics: Establishing Face, Content, and Construct Validity in a Cadaveric Model.Arthroscopy. 2020 Jan;36(1):71-79.e1. doi: 10.1016/j.arthro.2019.07.016. Arthroscopy. 2020. PMID: 31864602
-
The Bankart Performance Metrics Combined With a Shoulder Model Simulator Create a Precise and Accurate Training Tool for Measuring Surgeon Skill.Arthroscopy. 2015 Sep;31(9):1639-54. doi: 10.1016/j.arthro.2015.04.092. Epub 2015 Jun 27. Arthroscopy. 2015. PMID: 26129726
-
The Bankart Performance Metrics Combined With a Cadaveric Shoulder Create a Precise and Accurate Assessment Tool for Measuring Surgeon Skill.Arthroscopy. 2015 Sep;31(9):1655-70. doi: 10.1016/j.arthro.2015.05.006. Epub 2015 Jul 31. Arthroscopy. 2015. PMID: 26238730
-
Arthroscopic Bankart repair.Clin Sports Med. 1996 Oct;15(4):737-51. Clin Sports Med. 1996. PMID: 8891405 Review.
-
A Meta-Analysis of Arthroscopic versus Open Repair for Treatment of Bankart Lesions in the Shoulder.Med Sci Monit. 2015 Oct 8;21:3028-35. doi: 10.12659/MSM.894346. Med Sci Monit. 2015. PMID: 26446430 Free PMC article.
Cited by
-
[Virtual arthroscopy : Gaming or training concept of the future].Unfallchirurg. 2019 Jun;122(6):431-438. doi: 10.1007/s00113-019-0653-5. Unfallchirurg. 2019. PMID: 31065737 Review. German.
-
Metric-Based Simulation Training to Proficiency for Endovascular Thrombectomy in Ischemic Stroke.Front Neurol. 2022 Sep 27;13:742263. doi: 10.3389/fneur.2022.742263. eCollection 2022. Front Neurol. 2022. PMID: 36237633 Free PMC article.
-
International expert consensus on a structured approach to robotic multiport right hemicolectomy with complete mesocolic excision and intracorporeal anastomosis.Colorectal Dis. 2025 Aug;27(8):e70197. doi: 10.1111/codi.70197. Colorectal Dis. 2025. PMID: 40785273 Free PMC article.
-
Development of performance and error metrics for ultrasound-guided axillary brachial plexus block.Adv Med Educ Pract. 2017 Apr 5;8:257-263. doi: 10.2147/AMEP.S128963. eCollection 2017. Adv Med Educ Pract. 2017. PMID: 28435344 Free PMC article.
-
Validation studies of virtual reality simulation performance metrics for mechanical thrombectomy in ischemic stroke.J Neurointerv Surg. 2019 Aug;11(8):775-780. doi: 10.1136/neurintsurg-2018-014510. Epub 2019 Jan 17. J Neurointerv Surg. 2019. PMID: 30655360 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources