Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jul 25;7(9):889-94.
doi: 10.4253/wjge.v7.i9.889.

Comparison of endoscopic stenting for malignant biliary obstruction: A single-center study

Affiliations

Comparison of endoscopic stenting for malignant biliary obstruction: A single-center study

Ryuichi Yamamoto et al. World J Gastrointest Endosc. .

Abstract

Aim: To evaluate the efficacy and safety of single-step endoscopic placement of self-expandable metallic stents (SEMS) for treatment of obstructive jaundice.

Methods: A retrospective study was performed among 90 patients who underwent transpapillary biliary metallic stent placement for malignant biliary obstruction (MBO) between April 2005 and October 2012. The diagnosis of primary disease and MBO was based on abdominal ultrasound, computed tomography, magnetic resonance imaging, endoscopic ultrasound, endoscopic retrograde cholangiopancreatography with brush cytology, biopsy, and/or a combination of these modalities. The type of SEMS (covered or non-covered, 8 mm or 10 mm in diameter) was determined by the endoscopist. Ninety patients were divided into two groups: group 1 (49 patients) who underwent a single-step SEMS placement and group 2 (41 patients) who underwent a two-step SEMS placement. The technical success rate, complication rate, stent patency, and patient survival rate were compared between the groups. In addition, to identify the clinical prognostic factors associated with patient survival, the following variables were evaluated in Cox-regression analysis: gender, age, etiology of MBO (pancreatic cancer or non-pancreatic cancer), clinical stage (IVb; with distant metastases or IVa >; without distant metastases), chemotherapy (with or without), patency of the stent, and the use of single-step or two-step SEMS.

Results: Immediate technical success was achieved in 93.9% (46/49) in group 1 and in 95.1% (39/41) in group 2, with no significant difference (P = 1.0). Similarly, there was no difference in the complication rates between the groups (group 1, 4.1% and group 2, 4.9%; P = 0.62). Stent failure was observed in 10 cases in group 1 (20.4%) and in 16 cases in group 2 (39.0%). The patency of stent and patient survival revealed no difference between the two groups with Kaplan-Meier analysis, with a mean patency of 111 ± 17 d in group 1 and 137 ± 19 d in group 2 (P = 0.91), and a mean survival of 178 ± 35 d in group 1 and 222 ± 23 d in group 2 (P = 0.57). On the contrary, the number of days of hospitalization associated with first-time SEMS placement in group 1 was shorter when compared with that number in group 2 (28 vs 39 d; P < 0.05). Multivariate analysis revealed that a clinical stage of IVa > (P = 0.0055), chemotherapy (P = 0.0048), and no patency of the stent (P = 0.011) were independent prognostic factors associated with patient survival.

Conclusion: Our results showed that single-step endoscopic metal stent placement was safe and effective for treating obstructive jaundice secondary to various inoperable malignancies.

Keywords: Endoscopic stenting; Malignant biliary obstruction; Self-expandable metallic stents; Single-step; Two-step.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Flowchart showing one-step and two-step self-expandable metal stent placement for distal malignant biliary obstruction. MBO: Malignant biliary obstruction; PTCD: Percutaneous transhepatic cholangiodrainage.
Figure 2
Figure 2
Kaplan-Meier curves showing the patency time of the stent in the single-step and two-step groups.
Figure 3
Figure 3
Kaplan-Meier curves showing the survival time of the patient in the single-step and two-step groups.

Similar articles

Cited by

References

    1. Huibregtse K, Cheng J, Coene PP, Fockens P, Tytgat GN. Endoscopic placement of expandable metal stents for biliary strictures--a preliminary report on experience with 33 patients. Endoscopy. 1989;21:280–282. - PubMed
    1. Neuhaus H, Hagenmüller F, Griebel M, Classen M. Percutaneous cholangioscopic or transpapillary insertion of self-expanding biliary metal stents. Gastrointest Endosc. 1991;37:31–37. - PubMed
    1. Knyrim K, Wagner HJ, Pausch J, Vakil N. A prospective, randomized, controlled trial of metal stents for malignant obstruction of the common bile duct. Endoscopy. 1993;25:207–212. - PubMed
    1. Lee MJ, Dawson SL, Mueller PR, Krebs TL, Saini S, Hahn PF. Palliation of malignant bile duct obstruction with metallic biliary endoprostheses: technique, results, and complications. J Vasc Interv Radiol. 1992;3:665–671. - PubMed
    1. Rossi P, Bezzi M, Rossi M, Adam A, Chetty N, Roddie ME, Iacari V, Cwikiel W, Zollikofer CL, Antonucci F. Metallic stents in malignant biliary obstruction: results of a multicenter European study of 240 patients. J Vasc Interv Radiol. 1994;5:279–285. - PubMed