Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
- PMID: 26241969
- DOI: 10.1109/TBME.2015.2462312
Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
Abstract
A flexible and conformable dry electrode design on nonwoven fabrics is examined as a sensing platform for biopotential measurements. Due to limitations of commercial wet electrodes (e.g., shelf life, skin irritation), dry electrodes are investigated as the potential candidates for long-term monitoring of ECG signals. Multilayered dry electrodes are fabricated by screen printing of Ag/AgCl conductive inks on flexible nonwoven fabrics. This study focuses on the investigation of skin-electrode interface, form factor design, electrode body placement of printed dry electrodes for a wearable sensing platform. ECG signals obtained with dry and wet electrodes are comparatively studied as a function of body posture and movement. Experimental results show that skin-electrode impedance is influenced by printed electrode area, skin-electrode interface material, and applied pressure. The printed electrode yields comparable ECG signals to wet electrodes, and the QRS peak amplitude of ECG signal is dependent on printed electrode area and electrode on body spacing. Overall, fabric-based printed dry electrodes present an inexpensive health monitoring platform solution for mobile wearable electronics applications by fulfilling user comfort and wearability.
Similar articles
-
Nonwoven fabric active electrodes for biopotential measurement during normal daily activity.IEEE Trans Biomed Eng. 2008 Jan;55(1):188-95. doi: 10.1109/TBME.2007.910678. IEEE Trans Biomed Eng. 2008. PMID: 18232361
-
Nanofiber web textile dry electrodes for long-term biopotential recording.IEEE Trans Biomed Circuits Syst. 2013 Apr;7(2):204-11. doi: 10.1109/TBCAS.2012.2201154. IEEE Trans Biomed Circuits Syst. 2013. PMID: 23853303
-
Fabric-based active electrode design and fabrication for health monitoring clothing.IEEE Trans Inf Technol Biomed. 2009 Mar;13(2):274-80. doi: 10.1109/TITB.2009.2012408. Epub 2009 Jan 23. IEEE Trans Inf Technol Biomed. 2009. PMID: 19174357
-
Recent Advances and Challenges in Textile Electrodes for Wearable Biopotential Signal Monitoring: A Comprehensive Review.Biosensors (Basel). 2023 Jun 26;13(7):679. doi: 10.3390/bios13070679. Biosensors (Basel). 2023. PMID: 37504078 Free PMC article. Review.
-
Electrode placement in electrocardiography smart garments: A review.J Electrocardiol. 2019 Nov-Dec;57:27-30. doi: 10.1016/j.jelectrocard.2019.08.015. Epub 2019 Aug 21. J Electrocardiol. 2019. PMID: 31473476 Review.
Cited by
-
Compensation for Electrode Detachment in Electrical Impedance Tomography with Wearable Textile Electrodes.Sensors (Basel). 2022 Dec 7;22(24):9575. doi: 10.3390/s22249575. Sensors (Basel). 2022. PMID: 36559943 Free PMC article.
-
A Low Contact Impedance Medical Flexible Electrode Based on a Pyramid Array Micro-Structure.Micromachines (Basel). 2020 Jan 1;11(1):57. doi: 10.3390/mi11010057. Micromachines (Basel). 2020. PMID: 31906344 Free PMC article.
-
Causes of Performance Degradation in Non-invasive Electromyographic Pattern Recognition in Upper Limb Prostheses.Front Neurorobot. 2018 Sep 21;12:58. doi: 10.3389/fnbot.2018.00058. eCollection 2018. Front Neurorobot. 2018. PMID: 30297994 Free PMC article. Review.
-
Bio-Signal Complexity Analysis in Epileptic Seizure Monitoring: A Topic Review.Sensors (Basel). 2018 May 26;18(6):1720. doi: 10.3390/s18061720. Sensors (Basel). 2018. PMID: 29861451 Free PMC article. Review.
-
Signal Quality Assessment of a Novel ECG Electrode for Motion Artifact Reduction.Sensors (Basel). 2021 Aug 18;21(16):5548. doi: 10.3390/s21165548. Sensors (Basel). 2021. PMID: 34450990 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources