Sources of systematic error in calibrated BOLD based mapping of baseline oxygen extraction fraction
- PMID: 26254114
- DOI: 10.1016/j.neuroimage.2015.07.059
Sources of systematic error in calibrated BOLD based mapping of baseline oxygen extraction fraction
Abstract
Recently a new class of calibrated blood oxygen level dependent (BOLD) functional magnetic resonance imaging (MRI) methods were introduced to quantitatively measure the baseline oxygen extraction fraction (OEF). These methods rely on two respiratory challenges and a mathematical model of the resultant changes in the BOLD functional MRI signal to estimate the OEF. However, this mathematical model does not include all of the effects that contribute to the BOLD signal, it relies on several physiological assumptions and it may be affected by intersubject physiological variability. The aim of this study was to investigate these sources of systematic error and their effect on estimating the OEF. This was achieved through simulation using a detailed model of the BOLD signal. Large ranges for intersubject variability in baseline physiological parameters such as haematocrit and cerebral blood volume were considered. Despite this the uncertainty in the relationship between the measured BOLD signals and the OEF was relatively low. Investigations of the physiological assumptions that underlie the mathematical model revealed that OEF measurements are likely to be overestimated if oxygen metabolism changes during hypercapnia or cerebral blood flow changes under hyperoxia. Hypoxic hypoxia was predicted to result in an underestimation of the OEF, whilst anaemic hypoxia was found to have only a minimal effect.
Keywords: Calibrated BOLD; FMRI; Hypercapnia; Hyperoxia; Oxygen extraction fraction; Oxygen metabolism.
Copyright © 2015. Published by Elsevier Inc.
Similar articles
-
Measurement of oxygen extraction fraction (OEF): An optimized BOLD signal model for use with hypercapnic and hyperoxic calibration.Neuroimage. 2016 Apr 1;129:159-174. doi: 10.1016/j.neuroimage.2016.01.021. Epub 2016 Jan 20. Neuroimage. 2016. PMID: 26801605
-
Measurement of OEF and absolute CMRO2: MRI-based methods using interleaved and combined hypercapnia and hyperoxia.Neuroimage. 2013 Dec;83:135-47. doi: 10.1016/j.neuroimage.2013.06.008. Epub 2013 Jun 13. Neuroimage. 2013. PMID: 23769703 Free PMC article. Clinical Trial.
-
Magnetic resonance imaging of resting OEF and CMRO₂ using a generalized calibration model for hypercapnia and hyperoxia.Neuroimage. 2012 Apr 2;60(2):1212-25. doi: 10.1016/j.neuroimage.2011.12.056. Epub 2011 Dec 29. Neuroimage. 2012. PMID: 22227047
-
A review of calibrated blood oxygenation level-dependent (BOLD) methods for the measurement of task-induced changes in brain oxygen metabolism.NMR Biomed. 2013 Aug;26(8):987-1003. doi: 10.1002/nbm.2847. Epub 2012 Sep 4. NMR Biomed. 2013. PMID: 22945365 Free PMC article. Review.
-
Principles of magnetic resonance assessment of brain function.J Magn Reson Imaging. 2006 Jun;23(6):794-807. doi: 10.1002/jmri.20587. J Magn Reson Imaging. 2006. PMID: 16649206 Review.
Cited by
-
Mapping oxidative metabolism in the human brain with calibrated fMRI in health and disease.J Cereb Blood Flow Metab. 2022 Jul;42(7):1139-1162. doi: 10.1177/0271678X221077338. Epub 2022 Mar 16. J Cereb Blood Flow Metab. 2022. PMID: 35296177 Free PMC article.
-
More homogeneous capillary flow and oxygenation in deeper cortical layers correlate with increased oxygen extraction.Elife. 2019 Jul 15;8:e42299. doi: 10.7554/eLife.42299. Elife. 2019. PMID: 31305237 Free PMC article.
-
Graded Hypercapnia-Calibrated BOLD: Beyond the Iso-metabolic Hypercapnic Assumption.Front Neurosci. 2017 May 18;11:276. doi: 10.3389/fnins.2017.00276. eCollection 2017. Front Neurosci. 2017. PMID: 28572755 Free PMC article.
-
Assessing the repeatability of absolute CMRO2, OEF and haemodynamic measurements from calibrated fMRI.Neuroimage. 2018 Jun;173:113-126. doi: 10.1016/j.neuroimage.2018.02.020. Epub 2018 Feb 14. Neuroimage. 2018. PMID: 29454105 Free PMC article.
-
Volume-localized measurement of oxygen extraction fraction in the brain using MRI.Magn Reson Med. 2019 Oct;82(4):1412-1423. doi: 10.1002/mrm.27823. Epub 2019 May 27. Magn Reson Med. 2019. PMID: 31131930 Free PMC article.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical