Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Dec 15:74:909-14.
doi: 10.1016/j.bios.2015.07.056. Epub 2015 Jul 29.

Graphene oxide quantum dots@silver core-shell nanocrystals as turn-on fluorescent nanoprobe for ultrasensitive detection of prostate specific antigen

Affiliations

Graphene oxide quantum dots@silver core-shell nanocrystals as turn-on fluorescent nanoprobe for ultrasensitive detection of prostate specific antigen

Haimeng Pei et al. Biosens Bioelectron. .

Abstract

We report a fluorescent turn-on nanoprobe for ultrasensitive detection of prostate specific antigen (PSA) based on graphene oxide quantum dots@silver (GQDs@Ag) core-shell nanocrystals. The success of this work relies on the assembly of quantities of GQDs in one GQDs@Ag probe, which makes the ratio of probe to target significantly increased and thus enables the fluorescent signal enhancement. When the silver shell was removed via oxidative etching using hydrogen peroxide (H2O2), the incorporated GQDs could be readily released and the whole process caused little change to their fluorescence performance. We tested the probe for the ultrasensitive detection of PSA based on the sandwich protocol of immunosensors. In particular, magnetic beads (MBs) were employed to immobilize anti-PSA antibody (Ab1) and acted as a separable capture probe, while GQDs@Ag was used as detection probe by linking antibody (Ab2). The developed immunosensor showed a good linear relationship between the fluorescence intensity and the concentration of PSA in the range from 1 pg/mL to 20 ng/mL with a detection limit of 0.3 pg/mL. The immunosensor used for the analysis of clinical serum samples exhibited satisfactory results, which demonstrated its potential for practical diagnostic applications. This method provides a possible solution to the application of GQDs in immunosensing and could be potentially extended to other similar systems.

Keywords: Fluorescent immunoassay; GQDs@Ag; Graphene oxide quantum dots; Magnetite; Prostate specific antigen.

PubMed Disclaimer

Publication types

LinkOut - more resources