Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jun;9(6):UC01-4.
doi: 10.7860/JCDR/2015/12083.6008. Epub 2015 Jun 1.

Fluid Administration Before Caesarean Delivery: Does Type and Timing Matter?

Affiliations

Fluid Administration Before Caesarean Delivery: Does Type and Timing Matter?

Poonam Arora et al. J Clin Diagn Res. 2015 Jun.

Abstract

Background: The effectiveness of fluid preloading is in doubt, so co-loading has been attempted to reduce the incidence of spinal anaesthesia induced hypotension in caesarean patients.

Aim: To compare crystalloid preloading, colloid preloading and colloid co-loading for prevention of maternal hypotension in caesarean delivery.

Settings and design: Study conducted in tertiary level hospital on 90 ASA I/II term parturients posted for elective caesarean section. Patients were randomly allocated to three Groups.

Materials and methods: Group A (n=30) was given 10 ml/kg of 6% hydroxyethyl starch (HES) 20 minutes prior to spinal anaesthesia, Group B (n=30) was given 10 ml/kg of 6% HES by rapid infusion in 10 minutes immediately after spinal anaesthesia and Group C (n=30) was given 10 ml/kg of Ringer's Lactate 20 minutes prior to spinal anaesthesia. Intraoperatively, Heart rate, systolic, diastolic and mean arterial pressure were recorded every five minutes. Episodes of hypotension were recorded and treated with bolus of 5 mg of ephedrine and total amount of ephedrine was noted. Adverse effects, if any were recorded.

Statistical analysis: ANNOVA for Quantitative Analysis and chi-Square test and Z-test for Qualitative Analysis.

Results: Baseline parameters were similar in all the three Groups. Heart rate decreased from the baseline in all the three Groups, however, mean heart rate was highest in Group C. Heart rate was statistically similar in Groups A and B. MAP decreased in all three Groups from baseline, however, highest fall was recorded in Group C whereas, MAP was statistically similar in Groups A and B. Incidence of hypotension was 66.66% in Group C as compared to 36.66% in Groups A and 40% in Group B respectively. Group C patients received 5.33±4.54 mg of ephedrine as compared to 2.00±2.82 mg in Group A and 2.33±3.14 mg in Group B. Thus, the incidence of hypotension and ephedrine consumption was significantly higher in Group C as compared to Groups A and B whereas, this difference was statistically not significant among Groups A and B.

Conclusion: Colloid preloading and co-loading are equally effective and both are superior to crystalloid preloading for prevention of maternal hypotension in caesarean section patients.

Keywords: Co-loading; Crystalloids; Preloading.

PubMed Disclaimer

Figures

[Table/Fig-2]:
[Table/Fig-2]:
Graphical representation for intraoperative trends in heart rate
[Table/Fig-3]:
[Table/Fig-3]:
Intraoperative Trends in Mean Arterial Pressure (MAP)
[Table/Fig-5]:
[Table/Fig-5]:
Incidence of hypotension
[Table/Fig-6]:
[Table/Fig-6]:
Number of boluses and total dose of ephedrine administered in the three Groups

References

    1. Ouerghi S, Bougacha MA, Frikha N, Mestiri T, Ben Ammar MS, Mebazaa MS. Combined use of crystalloid preload and low dose spinal anaesthesia for preventing hypotension in spinal anaesthesia for caesarean delivery: a randomized controlled trial. Middle East J Anaesthesiol. 2010;20(5):667–72. - PubMed
    1. Jackson R, Reid JA, Thorburn J. Volume Preloading is not essential to prevent spinal-induced hypotension at caesarean section. Br J Anaesth. 1995;75(3):262–65. - PubMed
    1. Holte K, Sharrock NE, Kehlet H. Pathophysiology and clinical implications of perioperative fluid excess. Br J Anaesth. 2002;89(4):622–32. - PubMed
    1. Mercier FJ, Bonnet MP, Dorie A. Spinal anaesthesia for caesarean section: fluid loading, vasopressors and hypotension. Ann Fr Anaesth Reanim. 2007;26:688–93. - PubMed
    1. Carvalho B, Mercier FJ, Riley ET, Brummel C, Cohen SE. Hetastarch co-loading is as effective as Preloading for the prevention of hypotension following spinal anaesthesia for caesarean delivery. Int J Obstet Anaesth. 2009;18(2):150–55. - PubMed

LinkOut - more resources