. 2015 Dec;148(6):1470-1476.
doi: 10.1378/chest.15-0516.

The Association Between Indwelling Arterial Catheters and Mortality in Hemodynamically Stable Patients With Respiratory Failure: A Propensity Score Analysis

Affiliations

The Association Between Indwelling Arterial Catheters and Mortality in Hemodynamically Stable Patients With Respiratory Failure: A Propensity Score Analysis

Douglas J Hsu et al. Chest. 2015 Dec.

Abstract

Background: Indwelling arterial catheters (IACs) are used extensively in the ICU for hemodynamic monitoring and for blood gas analysis. IAC use also poses potentially serious risks, including bloodstream infections and vascular complications. The purpose of this study was to assess whether IAC use was associated with mortality in patients who are mechanically ventilated and do not require vasopressor support.

Methods: This study used the Multiparameter Intelligent Monitoring in Intensive Care II database, consisting of > 24,000 patients admitted to the Beth Israel Deaconess Medical Center ICU between 2001 and 2008. Patients requiring mechanical ventilation who did not require vasopressors or have a diagnosis of sepsis were identified, and the primary outcome was 28-day mortality. A model based on patient demographics, comorbidities, vital signs, and laboratory results was developed to estimate the propensity for IAC placement. Patients were then propensity matched, and McNemar test was used to evaluate the association of IAC with 28-day mortality.

Results: We identified 1,776 patients who were mechanically ventilated who met inclusion criteria. There were no differences in the covariates included in the final propensity model between the IAC and non-IAC propensity-matched groups. For the matched cohort, there was no difference in 28-day mortality between the IAC group and the non-IAC group (14.7% vs 15.2%; OR, 0.96; 95% CI, 0.62-1.47).

Conclusions: In hemodynamically stable patients who are mechanically ventilated, the presence of an IAC is not associated with a difference in 28-day mortality. Validation in other datasets, as well as further analyses in other subgroups, is warranted.

PubMed Disclaimer

Figures

Figure 1 –
Figure 1 –
Flowchart of patient inclusion. CSRU = cardiac surgery recovery unit; IAC = indwelling arterial catheter; MIMIC-II = Multiparameter Intelligent Monitoring in Intensive Care-II.
Figure 2 –
Figure 2 –
A-D, Propensity score distribution plot comparing non-IAC (A, C) and IAC (B, D) groups before (A, B) and after (C, D) matching. See Figure 1 legend for expansion of abbreviation.
Figure 3 –
Figure 3 –
Sensitivity analyses of various matching caliper levels. A, ORs. B, P values.

References

    1. Angus DC, Shorr AF, White A, Dremsizov TT, Schmitz RJ, Kelley MA; Committee on Manpower for Pulmonary and Critical Care Societies (COMPACCS). Critical care delivery in the United States: distribution of services and compliance with Leapfrog recommendations. Crit Care Med. 2006;34(4):1016-1024. - PubMed
    1. Gershengorn HB, Garland A, Kramer A, Scales DC, Rubenfeld G, Wunsch H. Variation of arterial and central venous catheter use in United States intensive care units. Anesthesiology. 2014;120(3):650-664. - PMC - PubMed
    1. Traoré O, Liotier J, Souweine B. Prospective study of arterial and central venous catheter colonization and of arterial- and central venous catheter-related bacteremia in intensive care units. Crit Care Med. 2005;33(6):1276-1280. - PubMed
    1. Maki DG, Kluger DM, Crnich CJ. The risk of bloodstream infection in adults with different intravascular devices: a systematic review of 200 published prospective studies. Mayo Clin Proc. 2006;81(9):1159-1171. - PubMed
    1. Scheer B, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6(3):199-204. - PMC - PubMed

Publication types

MeSH terms