Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Feb;43(2):288-295.
doi: 10.1007/s00259-015-3163-x. Epub 2015 Aug 18.

Assessment of endothelial function and myocardial flow reserve using (15)O-water PET without attenuation correction

Affiliations

Assessment of endothelial function and myocardial flow reserve using (15)O-water PET without attenuation correction

Stéphane Tuffier et al. Eur J Nucl Med Mol Imaging. 2016 Feb.

Abstract

Purpose: Myocardial blood flow (MBF) measurement using positron emission tomography (PET) from the washout rate of (15)O-water is theoretically independent of tissue attenuation. The aim of this study was to evaluate the impact of not using attenuation correction in the assessment of coronary endothelial function and myocardial flow reserve (MFR) using (15)O-water PET.

Methods: We retrospectively processed 70 consecutive (15)O-water PET examinations obtained at rest and during cold pressor testing (CPT) in patients with dilated cardiomyopathy (n = 58), or at rest and during adenosine infusion in heart transplant recipients (n = 12). Data were reconstructed with attenuation correction (AC) and without attenuation correction (NAC) using filtered backprojection, and MBF was quantified using a single compartmental model. The agreement between AC and NAC data was assessed using Lin's concordance correlation coefficient followed by Bland-Altman plot analysis.

Results: Regarding endothelial function, NAC PET showed poor reproducibility and poor agreement with AC PET data. Conversely, NAC PET demonstrated high reproducibility and a strong agreement with AC PET for the assessment of MFR.

Conclusion: Non-attenuation-corrected (15)O-water PET provided an accurate measurement of MFR compared to attenuation-corrected PET. However, non-attenuation-corrected PET data were less effective for the assessment of endothelial function using CPT in this population.

Keywords: 15O-water; Attenuation correction; Endothelial function; Myocardial flow reserve; Myocardial perfusion; Positron emission tomography.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Nucl Cardiol. 2016 Jun;23(3):511-3 - PubMed
    1. Biometrics. 1989 Mar;45(1):255-68 - PubMed
    1. Cardiovasc Res. 2001 Apr;50(1):151-61 - PubMed
    1. Circulation. 1984 Oct;70(4):724-33 - PubMed
    1. J Nucl Med. 2004 Aug;45(8):1299-304 - PubMed

Publication types

LinkOut - more resources