Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2015 Dec;27(12):E312-8.
Epub 2015 Aug 25.

Evaluation of the Safety and Efficacy of the Novel Svelte Acrobat Integrated Delivery System via Radial Approach With 5 Fr Catheters

Affiliations
  • PMID: 26301560
Free article
Multicenter Study

Evaluation of the Safety and Efficacy of the Novel Svelte Acrobat Integrated Delivery System via Radial Approach With 5 Fr Catheters

Fernando Stucchi Devito et al. J Invasive Cardiol. 2015 Dec.
Free article

Abstract

Purpose: To evaluate the safety and efficacy of the Svelte Acrobat integrated delivery system (IDS) via radial approach with 5 Fr catheters. The direct stenting (DS) system enables easy delivery, deployment, and postdilatation of a cobalt-chromium stent.

Methods: Patients with coronary artery disease (CAD) were prospectively enrolled at three centers to undergo percutaneous coronary intervention with DS via radial approach using 5 Fr catheters. The primary endpoint was IDS success, which was defined as DS without postdilatation and final stenosis <20% with Thrombolysis in Myocardial Infarction (TIMI)-3 flow.

Results: Fifty consecutive patients with 55 lesions were included. The procedure success rate was 98%. The device could not cross the lesion in 2 cases, so DS success was 96%. Fifty lesions met the primary study objective; thus, IDS success rate was 91%. The procedure duration was 21 ± 9 minutes, fluoroscopy time was 7.3 ± 4.7 minutes, and contrast volume per vessel was 103 ± 33 cm3. The final residual stenosis, by quantitative coronary angiography, was 3.4 ± 4%. The reduced need for additional catheters resulted in a 20% procedural cost reduction. There were no bleeding or vascular complications. At 8 months, the event-free survival rate was 84%.

Conclusions: DS using the Svelte Acrobat IDS via radial approach with low-profile catheters is safe and efficacious in select coronary artery disease patients, and its use is associated with potential procedural cost savings.

PubMed Disclaimer

LinkOut - more resources