. 2016 Jan;45(1):19-28.
doi: 10.1007/s00256-015-2236-z. Epub 2015 Aug 25.

The femoral neck-shaft angle on plain radiographs: a systematic review

Affiliations

The femoral neck-shaft angle on plain radiographs: a systematic review

Christoph Kolja Boese et al. Skeletal Radiol. 2016 Jan.

Abstract

Objective: The femoral neck-shaft angle (NSA) is an important measure for the assessment of the anatomy of the hip and planning of operations. Despite its common use, there remains disagreement concerning the method of measurement and the correction of hip rotation and femoral version of the projected NSA on conventional radiographs. We addressed the following questions: (1) What are the reported values for NSA in normal adult subjects and in osteoarthritis? (2) Is there a difference between non-corrected and rotation-corrected measurements? (3) Which methods are used for measuring the NSA on plain radiographs? (4) What could be learned from an analysis of the intra- and interobserver reliability?

Material and methods: A systematic literature search was performed including 26 publications reporting the measurement of the NSA on conventional radiographs.

Results: The mean NSA of healthy adults (5,089 hips) was 128.8° (98-180°) and 131.5° (115-155°) in patients with osteoarthritis (1230 hips). The mean NSA was 128.5° (127-130.5°) for the rotation-corrected and 129.5° (119.6-151°) for the non-corrected measurements.

Conclusion: Our data showed a high variance of the reported neck-shaft angles. Notably, we identified the inconsistency of the published methods of measurement as a central issue. The reported effect of rotation-correction cannot be reliably verified.

Keywords: CCD; Caput-collum-diaphyseal angle; Hip anatomy; Hip arthroplasty; NSA; Neck shaft angle.

PubMed Disclaimer

References

    1. J Bone Joint Surg Br. 1998 Jul;80(4):711-9 - PubMed
    1. Z Orthop Ihre Grenzgeb. 1972 Feb;110(1):76-82 - PubMed
    1. J Arthroplasty. 1987;2(2):99-109 - PubMed
    1. Br J Radiol. 2014 May;87(1037):20130358 - PubMed
    1. Radiologe. 1986 Jun;26(6):293-304 - PubMed

Publication types

LinkOut - more resources