. 2015 Oct;93(10):893-901.
doi: 10.1139/cjpp-2014-0474. Epub 2015 May 7.

Assessment of donor heart viability during ex vivo heart perfusion

Affiliations

Assessment of donor heart viability during ex vivo heart perfusion

Christopher W White et al. Can J Physiol Pharmacol. 2015 Oct.

Abstract

Ex vivo heart perfusion (EVHP) may facilitate resuscitation of discarded donor hearts and expand the donor pool; however, a reliable means of demonstrating organ viability prior to transplantation is required. Therefore, we sought to identify metabolic and functional parameters that predict myocardial performance during EVHP. To evaluate the parameters over a broad spectrum of organ function, we obtained hearts from 9 normal pigs and 37 donation after circulatory death pigs and perfused them ex vivo. Functional parameters obtained from a left ventricular conductance catheter, oxygen consumption, coronary vascular resistance, and lactate concentration were measured, and linear regression analyses were performed to identify which parameters best correlated with myocardial performance (cardiac index: mL·min(-1)·g(-1)). Functional parameters exhibited excellent correlation with myocardial performance and demonstrated high sensitivity and specificity for identifying hearts at risk of poor post-transplant function (ejection fraction: R(2) = 0.80, sensitivity = 1.00, specificity = 0.85; stroke work: R(2) = 0.76, sensitivity = 1.00, specificity = 0.77; minimum dP/dt: R(2) = 0.74, sensitivity = 1.00, specificity = 0.54; tau: R(2) = 0.51, sensitivity = 1.00, specificity = 0.92), whereas metabolic parameters were limited in their ability to predict myocardial performance (oxygen consumption: R(2) = 0.28; coronary vascular resistance: R(2) = 0.20; lactate concentration: R(2) = 0.02). We concluded that evaluation of functional parameters provides the best assessment of myocardial performance during EVHP, which highlights the need for an EVHP device capable of assessing the donor heart in a physiologic working mode.

Keywords: consommation d’oxygène; ex vivo heart perfusion; functional assessment; greffe cardiaque; heart transplant; lactate metabolism; machine de perfusion; machine perfusion; métabolisme de l’acide lactique; organ evaluation; organ preservation; oxygen consumption; perfusion cardiaque ex vivo; préservation des organes; évaluation des organes; évaluation fonctionnelle.

PubMed Disclaimer

Publication types

Substances