Observational Study
. 2016 Jan;61(1):208-14.
doi: 10.1007/s10620-015-3851-1. Epub 2015 Aug 30.

Correlation Between Capillary and Venous Blood Glucose in the Lactose Tolerance Test

Affiliations
Observational Study

Correlation Between Capillary and Venous Blood Glucose in the Lactose Tolerance Test

José Luis Domínguez Jiménez et al. Dig Dis Sci. 2016 Jan.

Abstract

Background: The lactose tolerance test is a classic method for the study of lactose malabsorption. However, the methodology used has not been standardized, and this leads to differences in results.

Aim: The aim of this report was to analyze whether capillary blood glucose measurement is in agreement with venous blood glucose when performing lactose tolerance test.

Methods: This is a prospective study of consecutive patients with suspected lactose malabsorption who had lactose tolerance test performed in venous and capillary blood simultaneously, using a load of 50 g lactose. Agreement was measured using the concordance correlation coefficient of Lin (95 % CI) and Bland-Altman plots. The degree of agreement was measured using the Kappa index. A value of p < 0.05 was considered statistically significant.

Results: Eighty-four patients (68 % women) were included. The concordance correlation coefficient showed very poor agreement between the two techniques: 0.68 (0.58-0.77), 0.72 (0.62-0.8), and 0.77 (0.69-0.83) for baseline, 30, and 60 min, respectively. The Bland-Altman plots showed that capillary blood glucose measurements result in higher levels than venous blood glucose measurements, with mean differences of 0.39, 0.77, and 1.1 mmol/L at baseline, 30, and 60 min, respectively. The degree of agreement was low, with a Kappa index of 0.59 (p < 0.001).

Conclusions: The test measured in venous blood is not in agreement with the measurement obtained from capillary blood. It is likely that the diagnostic accuracy attributed without distinction to lactose tolerance test in different studies for lactose malabsorption is incorrect, making it necessary to specify the analysis method.

Keywords: Glycemic variability; Lactose intolerance diagnosis; Lactose malabsorption; Lactose tolerance test.

PubMed Disclaimer

Similar articles

Cited by

References

    1. J Gastroenterol Hepatol. 2013 Sep;28(9):1462-8 - PubMed
    1. World J Gastrointest Pharmacol Ther. 2012 Jun 6;3(3):29-33 - PubMed
    1. J Diabetes Sci Technol. 2009 Jul 01;3(4):903-13 - PubMed
    1. Clin Chem Lab Med. 2013 Oct;51(10):1883-5 - PubMed
    1. J Diabetes Sci Technol. 2010 Nov 01;4(6):1479-94 - PubMed

Publication types

MeSH terms

LinkOut - more resources