Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy
- PMID: 26335703
- DOI: 10.1177/1533034615601280
Dosimetric Comparison Between 3-Dimensional Conformal and Robotic SBRT Treatment Plans for Accelerated Partial Breast Radiotherapy
Abstract
Accelerated partial breast irradiation is an attractive alternative to conventional whole breast radiotherapy for selected patients. Recently, CyberKnife has emerged as a possible alternative to conventional techniques for accelerated partial breast irradiation. In this retrospective study, we present a dosimetric comparison between 3-dimensional conformal radiotherapy plans and CyberKnife plans using circular (Iris) and multi-leaf collimators. Nine patients who had undergone breast-conserving surgery followed by whole breast radiation were included in this retrospective study. The CyberKnife planning target volume (PTV) was defined as the lumpectomy cavity + 10 mm + 2 mm with prescription dose of 30 Gy in 5 fractions. Two sets of 3-dimensional conformal radiotherapy plans were created, one used the same definitions as described for CyberKnife and the second used the RTOG-0413 definition of the PTV: lumpectomy cavity + 15 mm + 10 mm with prescription dose of 38.5 Gy in 10 fractions. Using both PTV definitions allowed us to compare the dose delivery capabilities of each technology and to evaluate the advantage of CyberKnife tracking. For the dosimetric comparison using the same PTV margins, CyberKnife and 3-dimensional plans resulted in similar tumor coverage and dose to critical structures, with the exception of the lung V5%, which was significantly smaller for 3-dimensional conformal radiotherapy, 6.2% when compared to 39.4% for CyberKnife-Iris and 17.9% for CyberKnife-multi-leaf collimator. When the inability of 3-dimensional conformal radiotherapy to track motion is considered, the result increased to 25.6%. Both CyberKnife-Iris and CyberKnife-multi-leaf collimator plans demonstrated significantly lower average ipsilateral breast V50% (25.5% and 24.2%, respectively) than 3-dimensional conformal radiotherapy (56.2%). The CyberKnife plans were more conformal but less homogeneous than the 3-dimensional conformal radiotherapy plans. Approximately 50% shorter treatment times and 50% lower number of delivered monitor units (MU) were achievable with CyberKnife-multi-leaf collimator than with CyberKnife-Iris. The CyberKnife-multi-leaf collimator treatment times were comparable to 3-dimensional conformal radiotherapy, however, the number of MU delivered was approximately 2.5 times larger. The suitability of 10 + 2 mm margins warrants further investigation.
Keywords: 3D-conformal radiotherapy; breast cancer; robotic; stereotactic body radiation therapy; stereotactic radiotherapy.
© The Author(s) 2015.
Similar articles
-
Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.Radiat Oncol. 2016 Feb 27;11:29. doi: 10.1186/s13014-016-0607-9. Radiat Oncol. 2016. PMID: 26919837 Free PMC article.
-
A phase I/II trial to evaluate three-dimensional conformal radiation therapy confined to the region of the lumpectomy cavity for Stage I/II breast carcinoma: initial report of feasibility and reproducibility of Radiation Therapy Oncology Group (RTOG) Study 0319.Int J Radiat Oncol Biol Phys. 2005 Dec 1;63(5):1531-7. doi: 10.1016/j.ijrobp.2005.06.024. Epub 2005 Sep 29. Int J Radiat Oncol Biol Phys. 2005. PMID: 16198508 Clinical Trial.
-
Accelerated partial breast irradiation: a dosimetric comparison of three different techniques.Brachytherapy. 2005;4(2):121-9. doi: 10.1016/j.brachy.2004.12.005. Brachytherapy. 2005. PMID: 15893265
-
[Dosimetric comparison of different techniques for external beam accelerated partial breast irradiation].Magy Onkol. 2016 Nov 29;60(4):305-311. Epub 2016 Jun 15. Magy Onkol. 2016. PMID: 27898749 Review. Hungarian.
-
[Conformal accelerated partial breast irradiation: state of the art].Cancer Radiother. 2012 Oct;16(7):641-9. doi: 10.1016/j.canrad.2012.03.006. Epub 2012 Jun 21. Cancer Radiother. 2012. PMID: 22727723 Review. French.
Cited by
-
Conventionally fractionated large volume head and neck re-irradiation using multileaf collimator-based robotic technique: A feasibility study.Clin Transl Radiat Oncol. 2020 Jul 2;24:102-110. doi: 10.1016/j.ctro.2020.06.012. eCollection 2020 Sep. Clin Transl Radiat Oncol. 2020. PMID: 32715109 Free PMC article.
-
Radiotoxicity in robotic radiosurgery: proposing a new quality index for optimizing the treatment planning of brain metastases.Radiat Oncol. 2017 Aug 17;12(1):136. doi: 10.1186/s13014-017-0867-z. Radiat Oncol. 2017. PMID: 28818094 Free PMC article.
-
Multicatheter interstitial brachytherapy versus stereotactic radiotherapy with CyberKnife for accelerated partial breast irradiation: a comparative treatment planning study with respect to dosimetry of organs at risk.Radiol Oncol. 2021 Mar 25;55(2):229-239. doi: 10.2478/raon-2021-0016. Radiol Oncol. 2021. PMID: 33768766 Free PMC article.
-
Partial breast irradiation with CyberKnife after breast conserving surgery: a pilot study in early breast cancer.Radiat Oncol. 2018 Mar 23;13(1):49. doi: 10.1186/s13014-018-0991-4. Radiat Oncol. 2018. PMID: 29566762 Free PMC article. Clinical Trial.
-
CyberKnife versus multicatheter interstitial brachytherapy for accelerated partial breast irradiation: a dosimetrical assessment with focus on organs at risk.Rep Pract Oncol Radiother. 2022 Mar 22;27(1):152-160. doi: 10.5603/RPOR.a2022.0011. eCollection 2022. Rep Pract Oncol Radiother. 2022. PMID: 35402040 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials