Abstract
Purpose: To investigate the feasibility of MR diffusion tensor imaging (DTI) of the median nerve using simultaneous multi-slice echo planar imaging (EPI) with blipped CAIPIRINHA.
Materials and methods: After federal ethics board approval, MR imaging of the median nerves of eight healthy volunteers (mean age, 29.4 years; range, 25-32) was performed at 3 T using a 16-channel hand/wrist coil. An EPI sequence (b-value, 1,000 s/mm(2); 20 gradient directions) was acquired without acceleration as well as with twofold and threefold slice acceleration. Fractional anisotropy (FA), mean diffusivity (MD) and quality of nerve tractography (number of tracks, average track length, track homogeneity, anatomical accuracy) were compared between the acquisitions using multivariate ANOVA and the Kruskal-Wallis test.
Results: Acquisition time was 6:08 min for standard DTI, 3:38 min for twofold and 2:31 min for threefold acceleration. No differences were found regarding FA (standard DTI: 0.620 ± 0.058; twofold acceleration: 0.642 ± 0.058; threefold acceleration: 0.644 ± 0.061; p ≥ 0.217) and MD (standard DTI: 1.076 ± 0.080 mm(2)/s; twofold acceleration: 1.016 ± 0.123 mm(2)/s; threefold acceleration: 0.979 ± 0.153 mm(2)/s; p ≥ 0.074). Twofold acceleration yielded similar tractography quality compared to standard DTI (p > 0.05). With threefold acceleration, however, average track length and track homogeneity decreased (p = 0.004-0.021).
Conclusion: Accelerated DTI of the median nerve is feasible. Twofold acceleration yields similar results to standard DTI.
Key points: • Standard DTI of the median nerve is limited by its long acquisition time. • Simultaneous multi-slice acquisition is a new technique for accelerated DTI. • Accelerated DTI of the median nerve yields similar results to standard DTI.
Keywords: Diffusion tensor imaging; Diffusion tractography; Echo-planar imaging; Median nerve; Simultaneous multi-slice.
Similar articles
-
Meta-analysis of the normal diffusion tensor imaging values of the median nerve and how they change in carpal tunnel syndrome.Sci Rep. 2021 Oct 22;11(1):20935. doi: 10.1038/s41598-021-00353-z. Sci Rep. 2021. PMID: 34686721 Free PMC article. Review.
-
Simultaneous Multislice Echo Planar Imaging With Blipped Controlled Aliasing in Parallel Imaging Results in Higher Acceleration: A Promising Technique for Accelerated Diffusion Tensor Imaging of Skeletal Muscle.Invest Radiol. 2015 Jul;50(7):456-63. doi: 10.1097/RLI.0000000000000151. Invest Radiol. 2015. PMID: 25811832
-
Simultaneous multislice readout-segmented echo planar imaging for accelerated diffusion tensor imaging of the mandibular nerve: A feasibility study.J Magn Reson Imaging. 2017 Sep;46(3):663-677. doi: 10.1002/jmri.25603. Epub 2017 Jan 9. J Magn Reson Imaging. 2017. PMID: 28067973
-
Distortion-free diffusion tensor imaging for evaluation of lumbar nerve roots: Utility of direct coronal single-shot turbo spin-echo diffusion sequence.Magn Reson Imaging. 2018 Jun;49:78-85. doi: 10.1016/j.mri.2018.01.003. Epub 2018 Jan 31. Magn Reson Imaging. 2018. PMID: 29408676
-
Clinical Value and Reliability of Quantitative Assessments of Lumbosacral Nerve Root Using Diffusion Tensor and Diffusion Weighted MR Imaging: A Systematic Review.J Magn Reson Imaging. 2024 Nov;60(5):1823-1839. doi: 10.1002/jmri.29213. Epub 2024 Jan 8. J Magn Reson Imaging. 2024. PMID: 38190195
Cited by
-
Diffusion Tensor Imaging of the Brachial Plexus: A Comparison between Readout-segmented and Conventional Single-shot Echo-planar Imaging.Magn Reson Med Sci. 2019 Apr 10;18(2):150-157. doi: 10.2463/mrms.mp.2018-0004. Epub 2018 Nov 9. Magn Reson Med Sci. 2019. PMID: 30416178 Free PMC article.
-
Meta-analysis of the normal diffusion tensor imaging values of the median nerve and how they change in carpal tunnel syndrome.Sci Rep. 2021 Oct 22;11(1):20935. doi: 10.1038/s41598-021-00353-z. Sci Rep. 2021. PMID: 34686721 Free PMC article. Review.
-
Diffusion tensor imaging combined with the dual-echo steady-state (DESS) protocol for the evaluation of the median nerve in the carpal tunnel: A preliminary study.Surg Neurol Int. 2024 Mar 29;15:110. doi: 10.25259/SNI_156_2024. eCollection 2024. Surg Neurol Int. 2024. PMID: 38628509 Free PMC article.
-
MR imaging of the temporomandibular joint: comparison between acquisitions at 7.0 T using dielectric pads and 3.0 T.Dentomaxillofac Radiol. 2017 Jan;46(1):20160280. doi: 10.1259/dmfr.20160280. Epub 2016 Dec 18. Dentomaxillofac Radiol. 2017. PMID: 27704872 Free PMC article.
-
Feasibility of Diffusion Tensor and Morphologic Imaging of Peripheral Nerves at Ultra-High Field Strength.Invest Radiol. 2018 Dec;53(12):705-713. doi: 10.1097/RLI.0000000000000492. Invest Radiol. 2018. PMID: 29979328 Free PMC article.
References
MeSH terms
LinkOut - more resources
Full Text Sources