Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Nov;39(11):2205-13.
doi: 10.1007/s00264-015-2984-3. Epub 2015 Sep 18.

Effect of humeral stem design on humeral position and range of motion in reverse shoulder arthroplasty

Affiliations

Effect of humeral stem design on humeral position and range of motion in reverse shoulder arthroplasty

Alexandre Lädermann et al. Int Orthop. 2015 Nov.

Abstract

Purpose: The impacts of humeral offset and stem design after reverse shoulder arthroplasty (RSA) have not been well-studied, particularly with regard to newer stems which have a lower humeral inclination. The purpose of this study was to analyze the effect of different humeral stem designs on range of motion and humeral position following RSA.

Methods: Using a three-dimensional computer model of RSA, a traditional inlay Grammont stem was compared to a short curved onlay stem with different inclinations (155°, 145°, 135°) and offset (lateralised vs medialised). Humeral offset, the acromiohumeral distance (AHD), and range of motion were evaluated for each configuration.

Results: Altering stem design led to a nearly 7-mm change in humeral offset and 4 mm in the AHD. Different inclinations of the onlay stems had little influence on humeral offset and larger influence on decreasing the AHD. There was a 10° decrease in abduction and a 5° increase in adduction between an inlay Grammont design and an onlay design with the same inclination. Compared to the 155° model, the 135° model improved adduction by 28°, extension by 24° and external rotation of the elbow at the side by 15°, but led to a decrease in abduction of 9°. When the tray was placed medially, on the 145° model, a 9° loss of abduction was observed.

Conclusions: With varus inclination prostheses (135° and 145°), elevation remains unchanged, abduction slightly decreases, but a dramatic improvement in adduction, extension and external rotation with the elbow at the side are observed.

Keywords: Arm position; Complications; Humeral offset; Impingement; Inlay and onlay design; Range of motion; Reverse total shoulder arthroplasty; Reverse tray.

PubMed Disclaimer

References

    1. J Bone Joint Surg Am. 2008 Dec;90(12):2606-15 - PubMed
    1. J Bone Joint Surg Br. 2004 Apr;86(3):388-95 - PubMed
    1. J Shoulder Elbow Surg. 2014 Sep;23(9):1289-95 - PubMed
    1. J Bone Joint Surg Br. 2011 Sep;93(9):1240-6 - PubMed
    1. J Bone Joint Surg Am. 2007 Jul;89(7):1476-85 - PubMed

LinkOut - more resources