Review
. 2015 Oct;8(5):580-9.
doi: 10.1093/ckj/sfv057. Epub 2015 Aug 8.

Optimizing haemodialysate composition

Affiliations
Review

Optimizing haemodialysate composition

Francesco Locatelli et al. Clin Kidney J. 2015 Oct.

Abstract

Survival and quality of life of dialysis patients are strictly dependent on the quality of the haemodialysis (HD) treatment. In this respect, dialysate composition, including water purity, plays a crucial role. A major aim of HD is to normalize predialysis plasma electrolyte and mineral concentrations, while minimizing wide swings in the patient's intradialytic plasma concentrations. Adequate sodium (Na) and water removal is critical for preventing intra- and interdialytic hypotension and pulmonary edema. Avoiding both hyper- and hypokalaemia prevents life-threatening cardiac arrhythmias. Optimal calcium (Ca) and magnesium (Mg) dialysate concentrations may protect the cardiovascular system and the bones, preventing extraskeletal calcifications, severe secondary hyperparathyroidism and adynamic bone disease. Adequate bicarbonate concentration [HCO3 (-)] maintains a stable pH in the body fluids for appropriate protein and membrane functioning and also protects the bones. An adequate dialysate glucose concentration prevents severe hyperglycaemia and life-threating hypoglycaemia, which can lead to severe cardiovascular complications and a worsening of diabetic comorbidities.

Keywords: chronic kidney disease; chronic renal insufficiency; haemodiafiltration; haemodialysis; secondary hyperparathyroidism.

PubMed Disclaimer

References

    1. Locatelli F, Covic A, Chazot C, et al. Optimal composition of the dialysate, with emphasis on its influence on blood pressure. Nephrol Dial Transplant 2004; 19: 785–796 - PubMed
    1. de Paula FM, Peixoto AJ, Pinto LV, et al. Clinical consequences of an individualized dialysate sodium prescription in hemodialysis patients. Kidney Int 2004; 66: 1232–1238 - PubMed
    1. Gotch FA, Lam MA, Prowitt M, et al. Preliminary clinical results with sodium-volume modeling of hemodialysis therapy. Proc Clin Dial Transplant Forum 1980; 10: 12–17 - PubMed
    1. Polaschegg HD. Automatic, non invasive intradialytic clearance measurement. Int J Artif Organs 1993; 16: 185–191 - PubMed
    1. Petitclerc T, Goux N, Reynier AL, et al. A model for non-invasive estimation of in vivo dialyzer performances and patient's conductivity during hemodialysis. Int J Artif Organs 1993; 16: 585–591 - PubMed