Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2016 Feb;32(2):295-305.
doi: 10.1016/j.arthro.2015.07.017. Epub 2015 Sep 28.

Repair of the Posterior Third of the Meniscus During Meniscus Allograft Transplantation: Conventional Inside-Out Repair Versus FasT-Fix All-Inside Repair

Affiliations
Comparative Study

Repair of the Posterior Third of the Meniscus During Meniscus Allograft Transplantation: Conventional Inside-Out Repair Versus FasT-Fix All-Inside Repair

Ji Hyun Ahn et al. Arthroscopy. 2016 Feb.

Abstract

Purpose: To compare conventional inside-out (IO) repair and all-inside (AI) repair for the posterior third of the meniscus during meniscus allograft transplantation (MAT).

Methods: Among the 64 enrolled patients, 31 patients underwent MAT with conventional IO repair, and 33 patients underwent MAT with AI repair using the FasT-Fix instrument for the posterior third of the meniscus allograft. All of the patients were retrospectively evaluated through clinical assessment at the last follow-up (54.3 months in the IO group and 55.4 months in the AI group) and through magnetic resonance imaging assessment for meniscal extrusion at 1 year postoperatively. Thirty patients (15 in each group) were evaluated through second-look arthroscopy at 1 year postoperatively.

Results: There was no significant difference in the mean Lysholm score (91.3 in the IO group and 92.3 in the AI group; P = .358) or the mean Tegner activity scale (7.1 in each group; P = .885) between the 2 groups. There was no significant difference in the mean meniscal extrusion (2.6 mm in the IO group and 2.8 mm in the AI group; P = .454), relative percentage of extrusion value (25.6% in the IO group and 24.7% in the AI group; P = .721), or meniscal healing on second-look arthroscopy (P = .796) between the 2 groups. The difference in operative time between the 2 groups was found to be statistically significant (169.9 minutes in the IO group and 123.3 minutes in the AI group; P < .001).

Conclusions: Our comparative study on the different techniques for posterior repair of meniscus allograft suggested that AI posterior repair using FasT-Fix could be an alternative method to conventional IO repair as it gives a similar postoperative result and requires a shorter operative time.