Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2016 Mar;27(3):433-7.
doi: 10.1007/s00192-015-2841-3. Epub 2015 Sep 30.

Digital assessment and quantification of pelvic organ prolapse (DPOP-Q): a randomised cross-over diagnostic agreement trial

Affiliations
Randomized Controlled Trial

Digital assessment and quantification of pelvic organ prolapse (DPOP-Q): a randomised cross-over diagnostic agreement trial

Ganesh Thiagamoorthy et al. Int Urogynecol J. 2016 Mar.

Abstract

Introduction: Pelvic Organ Prolapse Quantification (POP-Q) system, measured in centimetres using a ruler (e.g. POPstix®), is recommended to quantify prolapse severity. POPstix® are costly (US $1/ruler). Home-made devices are used instead, but these have not been shown to be reproducible.

Hypothesis: Digitally assessed POP-Q (DPOP-Q) is as reliable, reproducible and acceptable as POP-Q assessed using POPstix®.

Methods: In this randomised crossover diagnostic agreement trial, each assessor measured the index finger of their dominant hand using a ruler. At visit one, patients were randomised to either POPstix® POP-Q assessment in a modified lithotomy position or DPOP-Q in both modified a lithotomy and a standing position. After the first clinician conducted this assessment, a second blinded clinician then carried out the remaining assessment on the same patient. For each examination, duration was recorded, along with a patient-completed discomfort score. Twenty-five women were invited for visit two, at which DPOP-Q was recorded by the same clinician who undertook DPOP-Q at the first visit. This allowed evaluation of inter- and intraobserver agreement together with examination acceptability.

Results: One hundred and nine women were recruited [median age 55 years, parity 2, body mass index (BMI) 27.1]. Of the 25 patients invited, 23 returned for visit two. DPOP-Q had high interobserver reliability [κ = 0.94, 95 % confidence interval (CI) 0.878-0.996] and intraobserver reliability (α = 0.96) with POPstix®. DPOP-Q was significantly quicker (p = 0.02) and less uncomfortable (p < 0.01) than POPstix® POP-Q.

Conclusion: DPOP-Q is reliable, acceptable and cost effective.

Keywords: POP-Q; Pelvic; Prolapse assessment; Vaginal.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Female Pelvic Med Reconstr Surg. 2012 Jan-Feb;18(1):37-40 - PubMed
    1. Int Braz J Urol. 2004 Nov-Dec;30(6):466-71 - PubMed
    1. Obstet Gynecol. 2004 Jul;104(1):37-41 - PubMed
    1. Clin Obstet Gynecol. 1972 Dec;15(4):1048-54 - PubMed
    1. Am J Obstet Gynecol. 1996 Jul;175(1):10-7 - PubMed

Publication types

LinkOut - more resources