Digital assessment and quantification of pelvic organ prolapse (DPOP-Q): a randomised cross-over diagnostic agreement trial
- PMID: 26423265
- DOI: 10.1007/s00192-015-2841-3
Digital assessment and quantification of pelvic organ prolapse (DPOP-Q): a randomised cross-over diagnostic agreement trial
Abstract
Introduction: Pelvic Organ Prolapse Quantification (POP-Q) system, measured in centimetres using a ruler (e.g. POPstix®), is recommended to quantify prolapse severity. POPstix® are costly (US $1/ruler). Home-made devices are used instead, but these have not been shown to be reproducible.
Hypothesis: Digitally assessed POP-Q (DPOP-Q) is as reliable, reproducible and acceptable as POP-Q assessed using POPstix®.
Methods: In this randomised crossover diagnostic agreement trial, each assessor measured the index finger of their dominant hand using a ruler. At visit one, patients were randomised to either POPstix® POP-Q assessment in a modified lithotomy position or DPOP-Q in both modified a lithotomy and a standing position. After the first clinician conducted this assessment, a second blinded clinician then carried out the remaining assessment on the same patient. For each examination, duration was recorded, along with a patient-completed discomfort score. Twenty-five women were invited for visit two, at which DPOP-Q was recorded by the same clinician who undertook DPOP-Q at the first visit. This allowed evaluation of inter- and intraobserver agreement together with examination acceptability.
Results: One hundred and nine women were recruited [median age 55 years, parity 2, body mass index (BMI) 27.1]. Of the 25 patients invited, 23 returned for visit two. DPOP-Q had high interobserver reliability [κ = 0.94, 95 % confidence interval (CI) 0.878-0.996] and intraobserver reliability (α = 0.96) with POPstix®. DPOP-Q was significantly quicker (p = 0.02) and less uncomfortable (p < 0.01) than POPstix® POP-Q.
Conclusion: DPOP-Q is reliable, acceptable and cost effective.
Keywords: POP-Q; Pelvic; Prolapse assessment; Vaginal.
Similar articles
-
Relationship of degree of uterine prolapse between pelvic examination in lithotomy position with cervical traction and pelvic examination in standing position.Int Urogynecol J. 2018 Aug;29(8):1173-1177. doi: 10.1007/s00192-018-3579-5. Epub 2018 Mar 6. Int Urogynecol J. 2018. PMID: 29508045
-
Turkish adaptation of the Pelvic Organ Prolapse Symptom Score and its validity and reliability.Int Urogynecol J. 2017 Aug;28(8):1217-1222. doi: 10.1007/s00192-016-3251-x. Epub 2017 Jan 6. Int Urogynecol J. 2017. PMID: 28062904
-
Validation of the pelvic organ prolapse quantification (POP-Q) system in left lateral position.Int Urogynecol J Pelvic Floor Dysfunct. 2009 Aug;20(8):979-83. doi: 10.1007/s00192-009-0884-z. Epub 2009 Apr 22. Int Urogynecol J Pelvic Floor Dysfunct. 2009. PMID: 19387526
-
How to use the Pelvic Organ Prolapse Quantification (POP-Q) system?Neurourol Urodyn. 2018 Aug;37(S6):S39-S43. doi: 10.1002/nau.23740. Neurourol Urodyn. 2018. PMID: 30614056 Review.
-
A review of the pelvic organ prolapse quantification system in China.Int Urogynecol J. 2016 Feb;27(2):287-90. doi: 10.1007/s00192-015-2830-6. Epub 2015 Sep 9. Int Urogynecol J. 2016. PMID: 26353847 Review.
Cited by
-
Matrix metalloproteinase-3 gene promoter polymorphisms: A potential risk factor for pelvic organ prolapse.Biomed Rep. 2016 Sep;5(3):337-343. doi: 10.3892/br.2016.736. Epub 2016 Aug 3. Biomed Rep. 2016. PMID: 27588175 Free PMC article.
-
Total vaginal length: Does it matter for assessing uterine prolapse?Int Urogynecol J. 2019 Aug;30(8):1279-1282. doi: 10.1007/s00192-018-3779-z. Epub 2018 Oct 24. Int Urogynecol J. 2019. PMID: 30357469
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical