Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2016 Mar;48(3):491-8.
doi: 10.1249/MSS.0000000000000777.

Comparison of Three Popular Exercise Modalities on V˙O2max in Overweight and Obese

Affiliations
Randomized Controlled Trial

Comparison of Three Popular Exercise Modalities on V˙O2max in Overweight and Obese

Fredrik Hjulstad Bækkerud et al. Med Sci Sports Exerc. 2016 Mar.

Abstract

Introduction: In this prospective randomized trial, we examined the effect of three popular exercise training modalities on maximal oxygen uptake (V˙O2max) in overweight and obese individuals. In addition, we examined possible concomitant adaptations in endurance exercise performance (time to exhaustion (TTE)), citrate synthase (CS) activity, venous and arterial function, blood volume, and calculated stroke volume (SV).

Methods: Thirty subjects were recruited (age, 41 ± 9 yr; weight, 91 ± 14 kg; height, 173 ± 8 cm; body mass index, 30 ± 4 kg·m(-2)) and randomized to either 6 wk of 4 × 4-min high-intensity interval training (4HIIT) at 85%-95% of HRmax, 10 × 1-min HIIT (1HIIT) at V˙O2max load, or 45-min moderate-intensity continuous training (MICT) at 70% of HRmax. V˙O2max, TTE, CS activity, venous and arterial function, as well as blood volume were measured before and after the training period. O2 pulse was calculated and used to estimate SV. Analysis was conducted per protocol.

Results: Only 4HIIT increased V˙O2max (P < 0.01) and significantly more compared with 1HIIT (P = 0.04) and MICT (P = 0.03) (4HIIT, 10%; 1HIIT, 3.3%; and MICT, 3.1%). All groups increased TTE (4HIIT, 198%; 1HIIT, 116%; MICT, 52%), with a higher increase after 4HIIT compared with that after MICT (P = 0.02). Calculated SV increased only after 4HIIT (14.4%). Plasma volume and hemoglobin mass increased after 1HIIT only (5.6% and 6.5%); however, no group differences were found. All groups increased CS activity (4HIIT, 35%; 1HIIT, 35%; MICT, 56%), with no group differences. Arterial inflow (15.7%) and venous outflow (22.7%) decreased after MICT, but there were no group differences.

Conclusions: 4HIIT was superior to 1HIIT and MICT in improving V˙O2max likely because of an increased SV.

PubMed Disclaimer

Publication types

Substances