. 2015 Oct;30(5):461-5.
doi: 10.1017/S1049023X15005038.

Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task

Affiliations

Accuracy of Tympanic Temperature Measurement in Firefighters Completing a Simulated Structural Firefighting Task

Toby Keene et al. Prehosp Disaster Med. 2015 Oct.

Abstract

Introduction: In the course of their duties, firefighters risk heat stroke and other medical conditions due to exertion in high-temperature environments. Infrared tympanic temperature measurement (TTym) is often used by Emergency Medical Services (EMS) to assess the core body temperature of firefighters. The accuracy of TTym in this setting has been called into question. Hypothesis/Problem This study aimed to examine the accuracy of TTym for core body temperature assessment at emergency firefighting events compared with gastrointestinal temperature measurement (TGI) as measured by ingestible thermometers.

Methods: Forty-five (42 male, three female) professional urban firefighters from an Australian fire service completed two 20-minute work periods in a 100°C (± 5°C) heat chamber while wearing personal protective clothing (PPC) and breathing apparatus (weighing approximately 22 kg). Measurements were taken immediately before entering, and on exiting, the heat chamber. Tympanic temperature was assessed by an infrared tympanic thermometer and TGI was measured by ingestible sensor and radio receiver.

Results: Complete data were available for 37 participants. Participant temperatures were higher on exiting the heat chamber than at baseline (TTym: 35.9°C (SD=0.7) vs 37.5°C (SD=0.8); TGI: 37.2°C (SD=0.4) vs 38.6°C (SD=0.5)). Tympanic temperature underestimated TGI on average by 1.3°C (SD=0.5) before entering the chamber and by 1.0°C (SD=0.8) following the exercise. Using pooled data, the average underestimation was 1.2°C (SD=0.7).

Conclusion: Tympanic thermometers cause an unreliable measure of core body temperature for firefighters engaged in fire suppression activities. Accurate and practical measures of core body temperature are required urgently.

Keywords: EMS Emergency Medical Services; Emergency Medical Services; PPC personal protective clothing; SCBA self-contained breathing apparatus; TGI gastrointestinal temperature measurement; TTym tympanic membrane temperaturemeasurement; body temperature; firefighters; thermometers.