. 2015 Nov;21(11):1362-6.
doi: 10.1016/j.parkreldis.2015.09.051. Epub 2015 Oct 1.

Identifying freezing of gait in Parkinson's disease during freezing provoking tasks using waist-mounted accelerometry

Affiliations

Identifying freezing of gait in Parkinson's disease during freezing provoking tasks using waist-mounted accelerometry

Heidemarie Zach et al. Parkinsonism Relat Disord. 2015 Nov.

Abstract

Background: Freezing of gait (FOG) is a common and debilitating phenomenon in Parkinson's disease (PD). Wearable accelerometers might help to assess FOG in the research setting. Here, we evaluate whether accelerometry can detect FOG while executing rapid full turns and while walking with rapid short steps (the two most common provoking circumstances for FOG).

Methods: We included 23 PD patients, who all had objective FOG. Participants performed several walking tasks, including walking rapidly with short steps and rapid full turns in both directions with a triaxial linear waist-mounted accelerometer. Two independent experts identified FOG episodes using off-line video-analysis (gold standard). A validated algorithm [ratio between pathological freezing (3-8 Hz)-and normal locomotor frequencies (0.5-3 Hz)] was applied on the accelerometer data to detect FOG episodes.

Results: Clinically, FOG was most often observed during full rapid turns (81% of all episodes), followed by walking with short rapid steps (12% of all episodes). During full rapid turns, accelerometry yielded a sensitivity of 78% and specificity of 59%. A sensitivity of 64% and specificity of 69% was observed during walking rapidly with small steps. Combining all tasks rendered a sensitivity of 75% and specificity of 76%.

Conclusion: Our results suggest that FOG can be detected from a single lumbar accelerometer during several walking tasks, including full rapid turns and walking with short steps rapidly, with reasonable sensitivity and specificity. This approach holds promise for possible implementation as complementary objective outcome in a research setting, but more work remains needed to improve the sensitivity and specificity.

Keywords: Accelerometry; Freeze index; Freezing of gait; Parkinson's disease.