Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Dec;43(12):1511-8.
doi: 10.1016/j.jdent.2015.10.001. Epub 2015 Oct 9.

Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva

Affiliations

Long-term sorption and solubility of bulk-fill and conventional resin-composites in water and artificial saliva

Ruwaida Z Alshali et al. J Dent. 2015 Dec.

Abstract

Objectives: To assess sorption and solubility of several bulk-fill and conventional resin-composites after one-year storage in water and artificial saliva (AS).

Methods: Six bulk-fill (SureFil SDR, Venus Bulk Fill, X-tra base, Filtek Bulk Fill flowable, Sonic Fill, and Tetric EvoCeram Bulk Fill) and eight conventional resin-composites (Grandioso Flow, Venus Diamond Flow, XFlow, Filtek Supreme XTE, Grandioso, Venus Diamond, TPH Spectrum, and Filtek Z250) were tested. Disc shaped samples (n=5) were randomly immersed into distilled water and AS for one-year period and weighed at different time intervals. Data were analysed using repeated measures ANOVA, one-way ANOVA, and Tukey's post hoc test (α=0.05).

Results: In water, all materials (with the exception of X-Flow) reached a stable mass within three months with a slow increase observed in AS up to one year. Sorption values in water and AS for most materials were not significantly different (p≥0.2). Sorption and solubility values in water ranged from (6.5 μg/mm(3) and -1.77 μg/mm(3) respectively) for X-tra base to (78.8 μg/mm(3) and 44.77 μg/mm(3) respectively) for X-Flow (p<0.005). Sorption of the polymer matrix in water ranged from 1.18% for XB to 9.95 % for XF.

Conclusions: Water sorption and solubility of resin-composites are material-dependent and highly affected by the filler loading and hydrophilicity of the resin matrix. BisEMA and UDMA-BisEMA based resins appeared to be more hydrophobic than BisGMA based systems. Water and AS, are generally comparable as storage media in terms of water sorption.

Clinical significance: Bulk-fill materials and conventional resin-composites tested varied in terms of sorption and solubility but both were considered stable in longterm water storage. The composition of each material is critical and can affect the long-term clinical performance of either type of resincomposites.

Keywords: Artificial saliva; Bulk-fill; Resin-composite; Solubility; Sorption; Water.

PubMed Disclaimer

LinkOut - more resources