Newborn physiological responses to noise in the neonatal unit
- PMID: 26480903
- PMCID: PMC9442682
- DOI: 10.1016/j.bjorl.2014.11.008
Newborn physiological responses to noise in the neonatal unit
Abstract
Introduction: The incorporation of technologies in the care of infants has contributed to increased survival; however, this has turned neonatal unit into a noisy environment.
Objective: To evaluate the physiological and functional effects resulting from the exposure to noise on low-weight newborns in incubators in a neonatal unit.
Methods: Prospective, observational, quantitative, exploratory, descriptive study. The adopted statistical method included tables of frequency, descriptive statistics, and Student's t-test, with a 0.05 level of significance. As data collection tools, the environmental noise and the noise inside of the incubator were evaluated, and the Assessment of Preterm Infant Behavior scale was used to assess premature newborn behavior and projected specifically to document the neurobehavioral functioning of preterm infants. The data collection occurred from September of 2012 to April of 2013; 61 low-weight newborns admitted in the neonatal unit and in incubators were observed.
Results: Significant differences in the variables heart rate and oxygen saturation were noted when newborns were exposed to noise.
Conclusion: Low-weight neonates in incubators present physiological alterations when facing discomfort caused by environmental noise in neonatal units.
Introdução: A incorporação de tecnologias no cuidado dos recém-nascidos contribui para o aumento da sobrevivência, porém, transformou as unidades neonatais em locais muito ruidosos.
Objetivo: Avaliar os efeitos fisiológicos e funcionais decorrentes de exposição a ruídos em uma unidade neonatal em recém-nascidos de baixo peso em incubadora.
Método: Estudo prospectivo, de caráter observacional, de abordagem quantitativa e natureza descritiva exploratória. O método estatístico utilizado foi o de tabelas de frequência, estatística descritiva e o teste t de student pareado, ao nível de significância de 0,05. Como instrumento de coleta dos dados foi avaliado o ruído ambiental e no interior das incubadoras e utilizada a escala assessment of preterm infant behavior para avaliação do comportamento dos bebês prematuros e projetada especificamente para documentar o funcionamento neurocomportamental dos bebês pré-termo. A coleta dos dados aconteceu no período de setembro de 2012 a abril de 2013 e foram observados 61 recém-nascidos de baixo peso em incubadora internados na unidade neonatal.
Resultados: Verifica-se a existência de diferenças significativas na variável frequência cardíaca e saturação de oxigênio frente à exposição a ruídos.
Conclusão: Recém-nascidos de baixo peso em incubadora apresentam alterações fisiológicas quando se encontram em desconforto causado pelo ruído ambiente de unidades neonatais.
Keywords: Audição; Efeitos do ruído; Hearing; Neonatologia; Neonatology; Noise; Noise effects; Premature birth; Recém-nascido de baixo peso; Ruído.
Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.
Similar articles
-
Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.Cochrane Database Syst Rev. 2020 Jan 27;1(1):CD010333. doi: 10.1002/14651858.CD010333.pub3. Cochrane Database Syst Rev. 2020. Update in: Cochrane Database Syst Rev. 2024 May 30;5:CD010333. doi: 10.1002/14651858.CD010333.pub4. PMID: 31986231 Free PMC article. Updated.
-
NICU noise and the preterm infant.Neonatal Netw. 2009 May-Jun;28(3):165-73. doi: 10.1891/0730-0832.28.3.165. Neonatal Netw. 2009. PMID: 19451078 Review.
-
Infants born very preterm react to variations of the acoustic environment in their incubator from a minimum signal-to-noise ratio threshold of 5 to 10 dBA.Pediatr Res. 2012 Apr;71(4 Pt 1):386-92. doi: 10.1038/pr.2011.76. Epub 2012 Feb 15. Pediatr Res. 2012. PMID: 22391640
-
Noise and the premature infant: physiological effects and practice implications.J Obstet Gynecol Neonatal Nurs. 2003 Jul-Aug;32(4):447-54. doi: 10.1177/0884217503255009. J Obstet Gynecol Neonatal Nurs. 2003. PMID: 12903694 Review.
-
Evaluation of noise in the neonatal intensive care unit.Am J Perinatol. 1996 Jan;13(1):37-41. doi: 10.1055/s-2007-994200. Am J Perinatol. 1996. PMID: 8645384
Cited by
-
Influence of the NICU on the Acoustic Isolation of a Neonatal Incubator.Front Pediatr. 2020 Sep 22;8:588. doi: 10.3389/fped.2020.00588. eCollection 2020. Front Pediatr. 2020. PMID: 33072664 Free PMC article.
-
Pilot clinical trial on supportive rehabilitation care in neonatal intensive unit. Influence of ambient noise on premature infants.J Perinatol. 2025 May 14. doi: 10.1038/s41372-025-02322-0. Online ahead of print. J Perinatol. 2025. PMID: 40369293 No abstract available.
-
Neonatal Nurses' Understanding of the Factors That Enhance and Hinder Early Communication Between Preterm Infants and Their Parents: A Narrative Inquiry Study.Int J Lang Commun Disord. 2025 Jul-Aug;60(4):e70093. doi: 10.1111/1460-6984.70093. Int J Lang Commun Disord. 2025. PMID: 40653954 Free PMC article.
-
Body size measuring techniques enabling stress-free growth monitoring of extreme preterm infants inside incubators: A systematic review.PLoS One. 2022 Apr 22;17(4):e0267285. doi: 10.1371/journal.pone.0267285. eCollection 2022. PLoS One. 2022. PMID: 35452486 Free PMC article.
-
RELATIONSHIP BETWEEN THE USE OF KANGAROO POSITION ON PRETERM BABIES AND MOTHER-CHILD INTERACTION UPON DISCHARGE.Rev Paul Pediatr. 2017 Apr-Jun;35(2):136-143. doi: 10.1590/1984-0462/;2017;35;2;00006. Rev Paul Pediatr. 2017. PMID: 28977331 Free PMC article.
References
-
- BRASIL . Ministério da Saúde; Brasília: 2010. Ministério da Saúde. Secretaria de Atenção à Saúde.
-
- Nogueira M.F.H. UERJ; Rio de Janeiro: 2011. Mensuração de ruído em unidades neonatais e incubadoras com recém-nascidos.
-
- Oliveira I.C.S. O advento das incubadoras e os cuidados de enfermagem aos prematuros na primeira metade do século XX. Texto Contexto Enferm Florianópolis. 2004;13:459–466.
-
- Santiago L. UTC; São Paulo: 2009. Humanização em UTI neonatal.
-
- Aurélio S.F., Tochetto T.M. Mensuração do ruído em uma UTI neonatal. Acta Pediátr Port. 2010;41:64–68.