Physical Activity Capture Technology With Potential for Incorporation Into Closed-Loop Control for Type 1 Diabetes
- PMID: 26481641
- PMCID: PMC4667300
- DOI: 10.1177/1932296815609949
Physical Activity Capture Technology With Potential for Incorporation Into Closed-Loop Control for Type 1 Diabetes
Abstract
Physical activity is an important determinant of glucose variability in type 1 diabetes (T1D). It has been incorporated as a nonglucose input into closed-loop control (CLC) protocols for T1D during the last 4 years mainly by 3 research groups in single center based controlled clinical trials involving a maximum of 18 subjects in any 1 study. Although physical activity data capture may have clinical benefit in patients with T1D by impacting cardiovascular fitness and optimal body weight achievement and maintenance, limited number of such studies have been conducted to date. Clinical trial registries provide information about a single small sample size 2 center prospective study incorporating physical activity data input to modulate closed-loop control in T1D that are seeking to build on prior studies. We expect an increase in such studies especially since the NIH has expanded support of this type of research with additional grants starting in the second half of 2015. Studies (1) involving patients with other disorders that have lasted 12 weeks or longer and tracked physical activity and (2) including both aerobic and resistance activity may offer insights about the user experience and device optimization even as single input CLC heads into real-world clinical trials over the next few years and nonglucose input is introduced as the next advance.
Keywords: closed loop; glucose insulin; physical activity capture devices; type 1 diabetes.
© 2015 Diabetes Technology Society.
Conflict of interest statement
Similar articles
-
Classification of Physical Activity: Information to Artificial Pancreas Control Systems in Real Time.J Diabetes Sci Technol. 2015 Oct 6;9(6):1200-7. doi: 10.1177/1932296815609369. J Diabetes Sci Technol. 2015. PMID: 26443291 Free PMC article.
-
Exercise and the Development of the Artificial Pancreas: One of the More Difficult Series of Hurdles.J Diabetes Sci Technol. 2015 Oct 1;9(6):1217-26. doi: 10.1177/1932296815609370. J Diabetes Sci Technol. 2015. PMID: 26428933 Free PMC article. Review.
-
Stress Testing of an Artificial Pancreas System With Pizza and Exercise Leads to Improvements in the System's Fuzzy Logic Controller.J Diabetes Sci Technol. 2015 Sep 14;9(6):1253-9. doi: 10.1177/1932296815602098. J Diabetes Sci Technol. 2015. PMID: 26370244 Free PMC article. Clinical Trial.
-
Fluctuations of Hyperglycemia and Insulin Sensitivity Are Linked to Menstrual Cycle Phases in Women With T1D.J Diabetes Sci Technol. 2015 Oct 14;9(6):1192-9. doi: 10.1177/1932296815608400. J Diabetes Sci Technol. 2015. PMID: 26468135 Free PMC article. Clinical Trial.
-
Diabetes technology and treatments in the paediatric age group.Int J Clin Pract Suppl. 2011 Feb;(170):76-82. doi: 10.1111/j.1742-1241.2010.02582.x. Int J Clin Pract Suppl. 2011. PMID: 21323816 Review.
Cited by
-
Closed loop control in adolescents and children during winter sports: Use of the Tandem Control-IQ AP system.Pediatr Diabetes. 2019 Sep;20(6):759-768. doi: 10.1111/pedi.12867. Epub 2019 May 23. Pediatr Diabetes. 2019. PMID: 31099946 Free PMC article. Clinical Trial.
-
Advances in Closed-Loop Insulin Delivery Systems in Patients with Type 1 Diabetes.Curr Diab Rep. 2018 Aug 29;18(10):88. doi: 10.1007/s11892-018-1051-z. Curr Diab Rep. 2018. PMID: 30159816 Review.
-
Multivariable Adaptive Artificial Pancreas System in Type 1 Diabetes.Curr Diab Rep. 2017 Aug 15;17(10):88. doi: 10.1007/s11892-017-0920-1. Curr Diab Rep. 2017. PMID: 28812204 Review.
-
Physical Activity and Psychological Stress Detection and Assessment of Their Effects on Glucose Concentration Predictions in Diabetes Management.IEEE Trans Biomed Eng. 2021 Jul;68(7):2251-2260. doi: 10.1109/TBME.2020.3049109. Epub 2021 Jun 17. IEEE Trans Biomed Eng. 2021. PMID: 33400644 Free PMC article.
-
Accuracy of Accelerometers for Measuring Physical Activity and Levels of Sedentary Behavior in Children: A Systematic Review.J Prim Care Community Health. 2019 Jan-Dec;10:2150132719874252. doi: 10.1177/2150132719874252. J Prim Care Community Health. 2019. PMID: 31509061 Free PMC article.
References
-
- Kovatchev BP, Clarke WL, Breton M, et al. Quantifying temporal glucose variability in diabetes via continuous glucose monitoring: mathematical methods and clinical application. Diabetes Technol Ther. 2005;7(6):849-862. - PubMed
-
- Shah VN, Shoskes A, Tawfik B, et al. Closed-loop system in the management of diabetes: past, present, and future. Diabetes Technol Ther. 2014;16(8):477-490. - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical