Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control
- PMID: 26489966
- DOI: 10.1002/dta.1906
Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control
Abstract
This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids.
Keywords: anabolic steroids; doping control; gas chromatography-mass spectrometry; ionization; liquid chromatography-tandem mass spectrometry; sensitivity.
Copyright © 2015 John Wiley & Sons, Ltd.
Similar articles
-
Analysis of anabolic androgenic steroids as sulfate conjugates using high performance liquid chromatography coupled to tandem mass spectrometry.Drug Test Anal. 2015 Nov-Dec;7(11-12):1030-9. doi: 10.1002/dta.1895. Epub 2015 Oct 16. Drug Test Anal. 2015. PMID: 26472592
-
Coupling of gas chromatography and electrospray ionization high resolution mass spectrometry for the analysis of anabolic steroids as trimethylsilyl derivatives in human urine.Anal Chim Acta. 2017 Apr 29;964:123-133. doi: 10.1016/j.aca.2017.01.058. Epub 2017 Feb 1. Anal Chim Acta. 2017. PMID: 28351628
-
Two-dimensional gas chromatography with heart-cutting for isotope ratio mass spectrometry analysis of steroids in doping control.Drug Test Anal. 2012 Dec;4(12):962-9. doi: 10.1002/dta.1379. Epub 2012 Jul 3. Drug Test Anal. 2012. PMID: 22761127
-
Complementary stable carbon isotope ratio and amount of substance measurements in sports anti-doping.Drug Test Anal. 2012 Dec;4(12):897-911. doi: 10.1002/dta.1378. Epub 2012 Jul 13. Drug Test Anal. 2012. PMID: 22791679 Review.
-
Ultra high performance liquid chromatography tandem mass spectrometry determination and profiling of prohibited steroids in human biological matrices. A review.J Chromatogr B Analyt Technol Biomed Life Sci. 2013 May 15;927:22-36. doi: 10.1016/j.jchromb.2012.12.003. Epub 2012 Dec 20. J Chromatogr B Analyt Technol Biomed Life Sci. 2013. PMID: 23317577 Review.
Cited by
-
Insights and prospects for ion mobility-mass spectrometry in clinical chemistry.Expert Rev Proteomics. 2022 Jan;19(1):17-31. doi: 10.1080/14789450.2022.2026218. Epub 2022 Jan 17. Expert Rev Proteomics. 2022. PMID: 34986717 Free PMC article.
-
Dried Urine Microsampling Coupled to Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) for the Analysis of Unconjugated Anabolic Androgenic Steroids.Molecules. 2020 Jul 14;25(14):3210. doi: 10.3390/molecules25143210. Molecules. 2020. PMID: 32674492 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous