Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings
- PMID: 26491105
- DOI: 10.1093/annhyg/mev075
Comparison of Air Impaction and Electrostatic Dust Collector Sampling Methods to Assess Airborne Fungal Contamination in Public Buildings
Abstract
Many ailments can be linked to exposure to indoor airborne fungus. However, obtaining a precise measurement of airborne fungal levels is complicated partly due to indoor air fluctuations and non-standardized techniques. Electrostatic dust collector (EDC) sampling devices have been used to measure a wide range of airborne analytes, including endotoxins, allergens, β-glucans, and microbial DNA in various indoor environments. In contrast, viable mold contamination has only been assessed in highly contaminated environments such as farms and archive buildings. This study aimed to assess the use of EDCs, compared with repeated air-impactor measurements, to assess airborne viable fungal flora in moderately contaminated indoor environments. Indoor airborne fungal flora was cultured from EDCs and daily air-impaction samples collected in an office building and a daycare center. The quantitative fungal measurements obtained using a single EDC significantly correlated with the cumulative measurement of nine daily air impactions. Both methods enabled the assessment of fungal exposure, although a few differences were observed between the detected fungal species and the relative quantity of each species. EDCs were also used over a 32-month period to monitor indoor airborne fungal flora in a hospital office building, which enabled us to assess the impact of outdoor events (e.g. ground excavations) on the fungal flora levels on the indoor environment. In conclusion, EDC-based measurements provided a relatively accurate profile of the viable airborne flora present during a sampling period. In particular, EDCs provided a more representative assessment of fungal levels compared with single air-impactor sampling. The EDC technique is also simpler than performing repetitive air-impaction measures over the course of several consecutive days. EDC is a versatile tool for collecting airborne samples and was efficient for measuring mold levels in indoor environments.
Keywords: airborne fungal flora; electrostatic dust collector; filamentous fungi; indoor air; molds; public buildings.
© The Author 2015. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
Similar articles
-
Comparison of sampling methods for the assessment of indoor microbial exposure.Indoor Air. 2012 Oct;22(5):405-14. doi: 10.1111/j.1600-0668.2012.00770.x. Epub 2012 Feb 28. Indoor Air. 2012. PMID: 22299641
-
Evaluation of a low-cost electrostatic dust fall collector for indoor air endotoxin exposure assessment.Appl Environ Microbiol. 2008 Sep;74(18):5621-7. doi: 10.1128/AEM.00619-08. Epub 2008 Aug 1. Appl Environ Microbiol. 2008. PMID: 18676704 Free PMC article.
-
beta-(1,3)-Glucan exposure assessment by passive airborne dust sampling and new sensitive immunoassays.Appl Environ Microbiol. 2010 Feb;76(4):1158-67. doi: 10.1128/AEM.01486-09. Epub 2009 Dec 28. Appl Environ Microbiol. 2010. PMID: 20038709 Free PMC article.
-
Sampling for indoor fungi.J Allergy Clin Immunol. 2004 Feb;113(2):189-98; quiz 199. doi: 10.1016/j.jaci.2003.11.021. J Allergy Clin Immunol. 2004. PMID: 14767427 Review.
-
Atmospheric transport of mold spores in clouds of desert dust.Arch Environ Health. 2003 Aug;58(8):498-504. Arch Environ Health. 2003. PMID: 15259429 Review.
Cited by
-
What's New in Prevention of Invasive Fungal Diseases during Hospital Construction and Renovation Work: An Overview.J Fungi (Basel). 2023 Jan 23;9(2):151. doi: 10.3390/jof9020151. J Fungi (Basel). 2023. PMID: 36836266 Free PMC article. Review.
-
Bulk isolation of basidiospores from wild mushrooms by electrostatic attraction with low risk of microbial contaminations.AMB Express. 2017 Dec;7(1):28. doi: 10.1186/s13568-017-0326-0. Epub 2017 Jan 25. AMB Express. 2017. PMID: 28124290 Free PMC article.
-
Season, Vegetation Proximity and Building Age Shape the Indoor Fungal Communities' Composition at City-Scale.J Fungi (Basel). 2022 Oct 3;8(10):1045. doi: 10.3390/jof8101045. J Fungi (Basel). 2022. PMID: 36294610 Free PMC article.
-
Efficiency of the Coriolis µ Air Sampling Device for Fungal Contamination Analysis of Indoor Air: A Case Study.Pathogens. 2025 Apr 3;14(4):345. doi: 10.3390/pathogens14040345. Pathogens. 2025. PMID: 40333156 Free PMC article.
-
Hospitalized Patient as Source of Aspergillus fumigatus, 2015.Emerg Infect Dis. 2018 Aug;24(8):1524-1527. doi: 10.3201/eid2408.171865. Emerg Infect Dis. 2018. PMID: 30014836 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical