Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2015:2015:621481.
doi: 10.1155/2015/621481. Epub 2015 Sep 27.

Are Biodegradable Osteosyntheses Still an Option for Midface Trauma? Longitudinal Evaluation of Three Different PLA-Based Materials

Affiliations
Clinical Trial

Are Biodegradable Osteosyntheses Still an Option for Midface Trauma? Longitudinal Evaluation of Three Different PLA-Based Materials

Andreas Kolk et al. Biomed Res Int. 2015.

Abstract

The aim was to evaluate three different biodegradable polylactic acid- (PLA-) based osteosynthesis materials (OM). These OM (BioSorb, LactoSorb, and Delta) were used in 64 patients of whom 55 (85.9%) had fractures of the zygoma, five (7.8%) in the LeFort II level, two of the frontal bone (3.1%), and two of the maxillary sinus wall (3.1%). In addition to routine follow-up (FU) at 3, 6, and 12 months (m) (T1, T2, and T3) all patients were finally evaluated at a mean FU after 14.1 m for minor (e.g., nerve disturbances, swelling, and pain) and major (e.g., infections and occlusal disturbances) complications. Out of all 64 patients 38 presented with complications; of these 28 were minor (43.8%) and 10 major (15.6%) resulting in an overall rate of 59.4%. Differences in minor complications regarding sensibility disturbance at T1 and T3 were statistically significant (P = 0.04). Differences between the OM were not statistically significant. Apart from sufficient mechanical stability for clinical use of all tested OM complications mostly involved pain and swelling probably mainly related to the initial bulk reaction attributable to the drop of pH value during the degradation process. This paper includes a review of the current aspects of biodegradable OM.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Intraoperative view. Adaption of biodegradable OM in the zygoma region.
Figure 2
Figure 2
Histologic evaluation of a biodegradable material (asterix). Surrounding foreign body reaction with giant-cell-formation (arrows).

Similar articles

Cited by

References

    1. Bowers D. G., Jr., Lynch J. B. Management of facial fractures. Southern Medical Journal. 1977;70(8):910–918. - PubMed
    1. Schmelzeisen R., McIff T., Rahn B. Further development of titanium miniplate fixation for mandibular fractures. Experience gained and questions raised from a prospective clinical pilot study with 2.0 mm fixation plates. Journal of Cranio-Maxillofacial Surgery. 1992;20(6):251–256. doi: 10.1016/s1010-5182(05)80437-8. - DOI - PubMed
    1. Fiala T. G. S., Novelline R. A., Yaremchuk M. J. Comparison of CT imaging artifacts from craniomaxillofacial internal fixation devices. Plastic and Reconstructive Surgery. 1993;92(7):1227–1232. - PubMed
    1. Wiener E., Pautke C., Link T. M., Neff A., Kolk A. Comparison of 16-slice MSCT and MRI in the assessment of squamous cell carcinoma of the oral cavity. European Journal of Radiology. 2006;58(1):113–118. doi: 10.1016/j.ejrad.2005.11.006. - DOI - PubMed
    1. Yu J. C., Bartlett S. P., Goldberg D. S., et al. An experimental study of the effects of craniofacial growth on the long-term positional stability of microfixation. The Journal of Craniofacial Surgery. 1996;7(1):64–68. doi: 10.1097/00001665-199601000-00014. - DOI - PubMed

Publication types