Pressure behavior of different PEEK materials for dental implants
- PMID: 26492595
- DOI: 10.1016/j.jmbbm.2015.10.003
Pressure behavior of different PEEK materials for dental implants
Abstract
Due to its mechanical properties, the biocompatible high-performance material PEEK (polyetheretherketone) and PEEK-based compounds may represent viable alternatives to titanium in the field of dental implantology. Therefore we performed static pressure tests with 11 PEEK materials (two unfilled grades, two grades filled with titanium-dioxide-powder, two grades filled with barium-sulfate-powder, two grades reinforced with short carbon fibers, one grade reinforced with glass fibers and two grades reinforced with continuous carbon fibers) in the form of cylindrical specimens with a diameter of 4, 5 and 6mm. The specimens had a height to diameter ratio of 2:1 and were therefore 8, 10 and 12mm high. The parameters elastic modulus, elastic limit and pressure strength were evaluated. The elastic moduli ranged between 2.65±0.03GPa for specimens of a titanium-dioxide-filled grade and 106.71±14.83GPa for specimens reinforced with continuous carbon fibers. The elastic limits ranged between 808.1±42.44N for specimens of a barium-sulfate-filled grade and 7256.4±519.86N for specimens reinforced with continuous carbon fibers. The lowest pressure strength of 122.77MPa was observed for specimens of an unfilled grade, whereas the highest pressure strength of 712.67±66.02MPa could be evaluated for specimens containing continuous carbon fibers. Regarding the maximum bite force of a first molar, all tested materials seem to be suitable for the use as dental implants.
Keywords: Carbon fibers; Dental implants; PEEK; Pressure behavior.
Copyright © 2015 Elsevier Ltd. All rights reserved.
Similar articles
-
Fatigue limits of different PEEK materials for dental implants.J Mech Behav Biomed Mater. 2017 May;69:163-168. doi: 10.1016/j.jmbbm.2016.12.019. Epub 2016 Dec 23. J Mech Behav Biomed Mater. 2017. PMID: 28081481
-
Finite element analysis of the biomechanical effects of PEEK dental implants on the peri-implant bone.J Biomech. 2015 Jan 2;48(1):1-7. doi: 10.1016/j.jbiomech.2014.11.017. Epub 2014 Nov 20. J Biomech. 2015. PMID: 25435385
-
Maximum insertion torque of a novel implant-abutment-interface design for PEEK dental implants.J Mech Behav Biomed Mater. 2018 Jan;77:85-89. doi: 10.1016/j.jmbbm.2017.09.005. Epub 2017 Sep 5. J Mech Behav Biomed Mater. 2018. PMID: 28898725
-
Carbon fiber-reinforced PEEK in implant dentistry: A scoping review on the finite element method.Comput Methods Biomech Biomed Engin. 2021 Sep;24(12):1355-1367. doi: 10.1080/10255842.2021.1888939. Epub 2021 Feb 22. Comput Methods Biomech Biomed Engin. 2021. PMID: 33616450
-
PEEK dental implants: a review of the literature.J Oral Implantol. 2013 Dec;39(6):743-9. doi: 10.1563/AAID-JOI-D-11-00002. Epub 2011 Sep 9. J Oral Implantol. 2013. PMID: 21905892 Review.
Cited by
-
TiO2 and PEEK Reinforced 3D Printing PMMA Composite Resin for Dental Denture Base Applications.Nanomaterials (Basel). 2019 Jul 22;9(7):1049. doi: 10.3390/nano9071049. Nanomaterials (Basel). 2019. PMID: 31336607 Free PMC article.
-
Fracture Characteristics of Commercial PEEK Dental Crowns: Combining the Effects of Aging Time and TiO2 Content.Polymers (Basel). 2023 Jun 17;15(12):2720. doi: 10.3390/polym15122720. Polymers (Basel). 2023. PMID: 37376366 Free PMC article.
-
Evaluation of Shear Bond Strength and Failure Modes of Lithium Disilicate Ceramic Veneering Material to Different High-Performance Polymers.Polymers (Basel). 2025 Feb 20;17(5):554. doi: 10.3390/polym17050554. Polymers (Basel). 2025. PMID: 40076048 Free PMC article.
-
Discoloration of PMMA, composite, and PEEK.Clin Oral Investig. 2017 May;21(4):1191-1200. doi: 10.1007/s00784-016-1892-2. Epub 2016 Jun 25. Clin Oral Investig. 2017. PMID: 27344329
-
Finite element evaluation to compare stress pattern in bone surrounding implant with carbon fiber-reinforced poly-ether-ether-ketone and commercially pure titanium implants.Natl J Maxillofac Surg. 2022 May-Aug;13(2):243-247. doi: 10.4103/njms.njms_354_21. Epub 2022 Jul 15. Natl J Maxillofac Surg. 2022. PMID: 36051812 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources