Skin photoplethysmography--a review
- PMID: 2649304
- DOI: 10.1016/0169-2607(89)90159-4
Skin photoplethysmography--a review
Abstract
The photoplethysmograph has been used for over 50 years but there are still misconceptions in how and what is the information obtained. A photoplethysmograph signal from any site on the skin can be separated into an oscillating (a.c.) and a steady-state (d.c.) component, their amplitudes dependent upon the structure and flow in the vascular bed. Many simple applications are available: pulse counters, using the a.c. component, skin colour and haemoglobin saturation meters, using the d.c. component. The d.c. component of the photoplethysmograph signal is a function of the blood flux beneath the device. A good emitter for use in a photoplethysmograph of skin blood flow is one in the frequency range 600-700 nm and the best signal for a.c. analysis is obtained from the finger pulp. The frequency range of the electronic circuitry should be from 0.01 to 15 Hz, then all the information in the signal can be extracted about the autonomic nervous system control of the cardiovascular system, particularly between 0.01 and 2 Hz. Comparative studies may be drawn between similar skin sites on a subject or between subjects if the afferent inputs to the brain stem are controlled or driven at a known frequency. These afferents, inputs, will modulate the efferents, outputs, which generate variations in the a.c. component of the detected photoplethysmograph signal.
Similar articles
-
Continuous postoperative free-flap monitoring with an EKG-interfaced photoplethysmograph.J Reconstr Microsurg. 1992 Jan;8(1):61-2. doi: 10.1055/s-2007-1006685. J Reconstr Microsurg. 1992. PMID: 1583618
-
High quality photoplethysmograph signals from a laser Doppler flowmeter: preliminary studies of two simultaneous outputs from the finger.J Biomed Eng. 1988 Oct;10(5):458-62. doi: 10.1016/0141-5425(88)90152-5. J Biomed Eng. 1988. PMID: 2976863
-
Observations on the photoplethysmograph pulse derived from a laser Doppler flowmeter.Clin Phys Physiol Meas. 1989 May;10(2):137-45. doi: 10.1088/0143-0815/10/2/003. Clin Phys Physiol Meas. 1989. PMID: 2743725
-
[Methods of microcirculatory monitoring (laser Doppler flowmetry, photoplethysmography and computer-assisted venous occlusion plethysmography)].Anasthesiol Intensivmed Notfallmed Schmerzther. 1996 May;31(1 Suppl):S37-43. Anasthesiol Intensivmed Notfallmed Schmerzther. 1996. PMID: 8737539 Review. German. No abstract available.
-
Photoplethysmography and its application in clinical physiological measurement.Physiol Meas. 2007 Mar;28(3):R1-39. doi: 10.1088/0967-3334/28/3/R01. Epub 2007 Feb 20. Physiol Meas. 2007. PMID: 17322588 Review.
Cited by
-
A multicentric validation study of a novel home sleep apnea test based on peripheral arterial tonometry.Sleep. 2022 May 12;45(5):zsac028. doi: 10.1093/sleep/zsac028. Epub 2022 Feb 2. Sleep. 2022. PMID: 35554589 Free PMC article.
-
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging.IEEE Trans Biomed Eng. 2016 Mar;63(3):463-77. doi: 10.1109/TBME.2015.2476337. Epub 2015 Sep 15. IEEE Trans Biomed Eng. 2016. PMID: 26390439 Free PMC article. Review.
-
The Measurement of Vital Signs in Pediatric Patients by Lifelight Software in Comparison to the Standard of Care: Protocol for the VISION-Junior Observational Study.JMIR Res Protoc. 2025 Mar 14;14:e58334. doi: 10.2196/58334. JMIR Res Protoc. 2025. PMID: 40085833 Free PMC article.
-
Measurement of Vital Signs by Lifelight Software in Comparison to Standard of Care Multisite Development (VISION-MD): Protocol for an Observational Study.JMIR Res Protoc. 2023 Jan 11;12:e41533. doi: 10.2196/41533. JMIR Res Protoc. 2023. PMID: 36630158 Free PMC article.
-
Photoplethysmography can replace hand-held Doppler in the measurement of ankle/brachial indices.Ann R Coll Surg Engl. 1998 Mar;80(2):96-8. Ann R Coll Surg Engl. 1998. PMID: 9623371 Free PMC article. Clinical Trial.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources