. 2015 Nov;205(5):985-90.
doi: 10.2214/AJR.15.14353.

Usefulness of Ultralow-Dose (Submillisievert) Chest CT Using Iterative Reconstruction for Initial Evaluation of Sharp Fish Bone Esophageal Foreign Body

Affiliations

Usefulness of Ultralow-Dose (Submillisievert) Chest CT Using Iterative Reconstruction for Initial Evaluation of Sharp Fish Bone Esophageal Foreign Body

Eun Young Kim et al. AJR Am J Roentgenol. 2015 Nov.

Abstract

Objective: The purpose of this article was to evaluate the usefulness of ultralow-dose chest CT as an initial imaging study for evaluation of sharp fish bone esophageal foreign body (FB).

Materials and methods: A total of 57 subjects who underwent ultralow-dose chest CT were included in this retrospective study. All subjects had a history of ingestion and symptoms of esophageal FB. All ultralow-dose chest CT data were reconstructed twice, once with filtered back projection (FBP) and once with iterative reconstruction, and three observers reviewed the images independently. ROC analysis was used to evaluate diagnostic performance of ultralow-dose chest CT. Intraclass correlation coefficient (ICC) was calculated for analysis of interobserver agreement.

Results: Among 57 patients, 42 were confirmed as having esophageal FB. Significant objective noise reduction of mediastinum was achieved using an iterative reconstruction technique. Subjective image noise of iterative reconstruction was significantly better than that of FBP. Overall diagnostic performance of ultralow-dose chest CT for esophageal FB of iterative reconstruction (AUC = 0.999) was significantly better than that of FBP (AUC = 0.95) (p = 0.02). Interobserver agreement was greater for iterative reconstruction (ICC = 0.944) than for FBP (ICC = 0.778).

Conclusion: Ultralow-dose chest CT using iterative reconstruction provided satisfactory diagnostic image quality for identifying fish bone esophageal FB with reduced radiation dose and high observer accuracy. Therefore, ultralow-dose chest CT would be adequate as a first-line imaging modality for fish bone esophageal FB.

Keywords: CT; esophagus; filtered back projection; foreign body ingestion; iterative reconstruction.