Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2016 Jan;17(1):1-8.
doi: 10.1093/ehjci/jev280. Epub 2015 Oct 24.

Intracardiac echocardiography for guidance of transcatheter aortic valve implantation under monitored sedation: a solution to a dilemma?

Affiliations
Review

Intracardiac echocardiography for guidance of transcatheter aortic valve implantation under monitored sedation: a solution to a dilemma?

Thomas Bartel et al. Eur Heart J Cardiovasc Imaging. 2016 Jan.

Abstract

Transcatheter aortic valve implantation (TAVI) has been established as a valuable alternative to surgical aortic valve replacement in patients deemed to have high or prohibitive perioperative risk. However, there are several technical constraints and procedural risks inherent to TAVI. These risks include annulus rupture, ventricular perforation, aortic dissection, coronary occlusion, and dislodgement or migration of the valve prosthesis to the aorta or the left ventricle (LV). Other complications may be related to inappropriate valve deployment and subsequent paravalvular leak. Most complications cannot be detected at an early stage without echocardiographic guidance. Although not addressed by current guidelines, some European centres have advocated a 'minimalist' approach with exclusively fluoroscopic and angiographic guidance. Transoesophageal echocardiography (TEE), including real-time three-dimensional (RT-3D) imaging, has been established as a standard approach for peri-interventional guidance of TAVI. However, TEE monitoring almost always necessitates general anaesthesia and endotracheal intubation. A potential alternative to TEE is intracardiac echocardiography (ICE) that may provide a solution to a common dilemma: the most important advantage of ICE being the compatibility with monitored anaesthesia care without endotracheal intubation. Other advantages of ICE include uninterrupted monitoring, no fluoroscopic interference, and precise Doppler-based assessment of pulmonary artery pressures. Limitations of ICE include the need for additional venous access, the learning curve associated with a new device, and potentially increased cost.

Keywords: intracardiac echocardiography; peri-procedural guidance; three-dimensional imaging; transcatheter aortic valve replacement; transoesophageal echocardiography.

PubMed Disclaimer

MeSH terms

Substances