. 2016 Mar;55(1):41-51.
doi: 10.1007/s00411-015-0624-3. Epub 2015 Oct 27.

The cytokinesis-blocked micronucleus assay: dose-response calibration curve, background frequency in the population and dose estimation

Affiliations

The cytokinesis-blocked micronucleus assay: dose-response calibration curve, background frequency in the population and dose estimation

E Rastkhah et al. Radiat Environ Biophys. 2016 Mar.

Abstract

An in vitro study of the dose responses of human peripheral blood lymphocytes was conducted with the aim of creating calibrated dose-response curves for biodosimetry measuring up to 4 Gy (0.25-4 Gy) of gamma radiation. The cytokinesis-blocked micronucleus (CBMN) assay was employed to obtain the frequencies of micronuclei (MN) per binucleated cell in blood samples from 16 healthy donors (eight males and eight females) in two age ranges of 20-34 and 35-50 years. The data were used to construct the calibration curves for men and women in two age groups, separately. An increase in micronuclei yield with the dose in a linear-quadratic way was observed in all groups. To verify the applicability of the constructed calibration curve, MN yields were measured in peripheral blood lymphocytes of two real overexposed subjects and three irradiated samples with unknown dose, and the results were compared with dose values obtained from measuring dicentric chromosomes. The comparison of the results obtained by the two techniques indicated a good agreement between dose estimates. The average baseline frequency of MN for the 130 healthy non-exposed donors (77 men and 55 women, 20-60 years old divided into four age groups) ranged from 6 to 21 micronuclei per 1000 binucleated cells. Baseline MN frequencies were higher for women and for the older age group. The results presented in this study point out that the CBMN assay is a reliable, easier and valuable alternative method for biological dosimetry.

Keywords: Baseline frequency; Biological dosimetry; Dose–response curve; Micronucleus.