Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Jan 15:452:99-105.
doi: 10.1016/j.cca.2015.10.026. Epub 2015 Oct 27.

A simple dried blood spot method for clinical pharmacological analyses of etoposide in cancer patients using liquid chromatography and fluorescence detection

Affiliations

A simple dried blood spot method for clinical pharmacological analyses of etoposide in cancer patients using liquid chromatography and fluorescence detection

Renata Režonja Kukec et al. Clin Chim Acta. .

Abstract

Background: Therapeutic drug monitoring of etoposide is not part of the routine clinical practice, however, measuring etoposide plasma concentration may be useful to prevent chemotherapy related adverse drug reactions. This paper describes the development and validation of a dried blood spot (DBS) assay for the determination of etoposide in blood samples of lung cancer patients.

Methods: The whole blood spot was cut out of the DBS card followed by sonication assisted liquid drug extraction. Extraction solution was evaporated and re-dissolved. A high-performance-liquid-chromatography method with fluorimetric detection ( λex=230nm; λem=330nm) was used.

Results: Method met the validation criteria in terms of selectivity, linearity (0.5-20.0μg/mL), accuracy (≥96.1%), precision (≤10.1%) and stability (long term 4weeks at room temperature and 40°C). Haematocrit did not influence DBS etoposide concentration. Good correlation between measured plasma and DBS concentrations was observed. The equation considering only haematocrit value was used for conversion of DBS to plasma concentration.

Conclusions: DBS sampling method showed comparable results to plasma samples. Therefore, it can be concluded that the developed and validated DBS method, which is more patient-friendly and requires less sample handling, is a reliable alternative to conventional plasma methods for measuring etoposide concentration in clinical pharmacological analyses.

Keywords: Dried blood spot; Etoposide; Lung cancer; Therapeutic drug monitoring.

PubMed Disclaimer

Publication types

LinkOut - more resources