Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2016 Dec;30(6):965-975.
doi: 10.1007/s10877-015-9801-9. Epub 2015 Oct 29.

A combination of experimental and finite element analyses of needle-tissue interaction to compute the stresses and deformations during injection at different angles

Affiliations

A combination of experimental and finite element analyses of needle-tissue interaction to compute the stresses and deformations during injection at different angles

Mahdi Halabian et al. J Clin Monit Comput. 2016 Dec.

Abstract

One of the main clinical applications of the needles is its practical usage in the femoral vein catheterization. Annually more than two million peoples in the United States are exposed to femoral vein catheterization. How to use the input needles into the femoral vein has a key role in the sense of pain in post-injection and possible injuries, such as tissue damage and bleeding. It has been shown that there might be a correlation between the stresses and deformations due to femoral injection to the tissue and the sense of pain and, consequently, injuries caused by needles. In this study, the stresses and deformations induced by the needle to the femoral tissue were experimentally and numerically investigated in response to an input needle at four different angles, i.e., 30°, 45°, 60°, and 90°, via finite element method. In addition, a set of experimental injections at different angles were carried out to compare the numerical results with that of the experimental ones, namely pain score. The results revealed that by increasing the angle of injection up to 60°, the strain at the interaction site of the needle-tissue is increased accordingly while a significant falling is observed at the angle of 90°. In contrast, the stress due to injection was decreased at the region of needle-tissue interaction with showing the lowest one at the angle of 90°. Experimental results were also well confirmed the numerical observations since the lowest pain score was seen at the angle of 90°. The results suggest that the most effective angle of injection would be 90° due to a lower amount of stresses and deformations compared to the other angles of injection. These findings may have implications not only for understating the stresses and deformations induced during injection around the needle-tissue interaction, but also to give an outlook to the doctors to implement the most suitable angle of injection in order to reduce the pain as well as post injury of the patients.

Keywords: Angle of injection; Finite element modeling; Needle–tissue interaction; Pain score; Vein tissue.

PubMed Disclaimer

References

    1. Proc Inst Mech Eng H. 2005 May;219(3):213-7 - PubMed
    1. J Biomech. 2014 Oct 17;47(13):3344-53 - PubMed
    1. Med Eng Phys. 2013 Oct;35(10 ):1518-24 - PubMed
    1. Eye (Lond). 2014 Jul;28(7):880-7 - PubMed
    1. Proc Inst Mech Eng H. 1997;211(4):335-47 - PubMed