Short Segment Spinal Instrumentation With Index Vertebra Pedicle Screw Placement for Pathologies Involving the Anterior and Middle Vertebral Column Is as Effective as Long Segment Stabilization With Cage Reconstruction: A Biomechanical Study
- PMID: 26536447
- DOI: 10.1097/BRS.0000000000001130
Short Segment Spinal Instrumentation With Index Vertebra Pedicle Screw Placement for Pathologies Involving the Anterior and Middle Vertebral Column Is as Effective as Long Segment Stabilization With Cage Reconstruction: A Biomechanical Study
Abstract
Study design: An in vitro, cadaveric biomechanical study.
Objective: The aim of the present study was to compare single-segment posterior instrumentation and fracture-level screws with single/multilevel posterior fixation and corpectomy in a simulated, unstable burst fracture model.
Summary of background data: The optimal extent of instrumentation for surgical cases of non-neoplastic vertebral body pathologies remains uncertain. Although several clinical studies demonstrate advantages of short segment instrumentation with index-level screws over more extensive corpectomy and anterior-posterior techniques, a comprehensive biomechanical comparison of these techniques is currently lacking.
Methods: Six bovine spines (T11-L5) were tested in flexion, extension, lateral bending (LB), and axial rotation (AR) following simulated burst fracture at L2. Posterior instrumentation included 1 level above/below (1LF) and 2 levels above/below fracture level (2LF), intermediate or index screws at fracture level (FF), and cross-connectors above/below fracture level (CC). Anterior corpectomy devices included expandable corpectomy spacers with/without integrated screws, ACDi and ACD, respectively FORTIFY-Integrated/FORTIFY; Globus Medical, Inc., PA. Constructs were tested in the following order: (1) Intact; (2) 1LF; (3) 1LF and CC; (4) 1LF and FF; (5) 1LF, CC, and FF; (6) 2LF; (7) 2LF and CC; (8) 2LF and FF; (9) 2LF, CC, and FF; (10) 2LF and ACD; (11) 2LF, ACD, and CC; (12) 1LF and ACDi; (13) 1LF, ACDi, and CC.
Results: During flexion, all constructs except 1LF reduced motion relative to intact (P ≤ 0.05). Anterior support was most stable, but no differences were found between constructs (P ≥ 0.05). Every construct reduced motion in extension, though no differences were found between constructs and intact (P ≥ 0.05). During LB, all constructs reduced motion relative to intact (P ≤ 0.05); 2LF constructs further reduced motion (P ≤ 0.05). No construct returned AR motion to intact, with significant increases in 1LF and ACDi, 2LF and ACD, and 2LF, ACD, and CC (P ≤ 0.05). Cross-connectors and fracture screws reinforced each other in posterior-only constructs, providing maximum stability (P ≥ 0.05).
Conclusions: This biomechanical comparison study found no significant superiority of combined anterior-posterior constructs over short segment fracture screw fixation, only multilevel posterior instrumentation with and without anterior support, providing increased stability in LB. Biomechanical equivalency suggests that short segment fracture screw intervention may provide appropriate stabilization for non-neoplastic pathologies involving the anterior and middle vertebral columns.
Level of evidence: 2.
Similar articles
-
Biomechanical analysis of anterior versus posterior instrumentation following a thoracolumbar corpectomy: Laboratory investigation.J Neurosurg Spine. 2014 Oct;21(4):577-81. doi: 10.3171/2014.6.SPINE13751. Epub 2014 Aug 1. J Neurosurg Spine. 2014. PMID: 25084029
-
Biomechanical analysis of four- versus six-screw constructs for short-segment pedicle screw and rod instrumentation of unstable thoracolumbar fractures.Spine J. 2014 Aug 1;14(8):1734-9. doi: 10.1016/j.spinee.2014.01.035. Epub 2014 Jan 23. Spine J. 2014. PMID: 24462814
-
Biomechanical evaluation of a simulated T-9 burst fracture of the thoracic spine with an intact rib cage.J Neurosurg Spine. 2014 Sep;21(3):481-8. doi: 10.3171/2014.5.SPINE13923. Epub 2014 Jun 20. J Neurosurg Spine. 2014. PMID: 24949903
-
MIS Expandable Interbody Spacers: A Literature Review and Biomechanical Comparison of an Expandable MIS TLIF With Conventional TLIF and ALIF.Spine (Phila Pa 1976). 2016 Apr;41 Suppl 8:S44-9. doi: 10.1097/BRS.0000000000001465. Spine (Phila Pa 1976). 2016. PMID: 26825792 Review.
-
Emerging Techniques for Posterior Fixation of the Lumbar Spine.J Am Acad Orthop Surg. 2016 Jun;24(6):357-64. doi: 10.5435/JAAOS-D-14-00378. J Am Acad Orthop Surg. 2016. PMID: 27077477 Review.
Cited by
-
Single-Level Rigid Fixation Combined with Coflex: A Biomechanical Study.Med Sci Monit. 2016 Mar 29;22:1022-7. doi: 10.12659/msm.896706. Med Sci Monit. 2016. PMID: 27021044 Free PMC article.
-
Functional and Radiological Outcomes of Short-Segment Fixation With Intermediate Screws for Thoracolumbar Spine Fractures.Cureus. 2024 Dec 13;16(12):e75653. doi: 10.7759/cureus.75653. eCollection 2024 Dec. Cureus. 2024. PMID: 39803062 Free PMC article.
-
A Dual-Screw Technique for Vertebral Compression Fractures via Robotic Navigation in the Osteopenic Lumbar Spine: An In-Vitro Biomechanical Analysis.Global Spine J. 2024 Jul;14(6):1706-1713. doi: 10.1177/21925682231152833. Epub 2023 Jan 15. Global Spine J. 2024. PMID: 36644787 Free PMC article.
-
Percutaneous monoplanar screws versus hybrid fixed axial and polyaxial screws in intermediate screw fixation for traumatic thoracolumbar burst fractures: a case-control study.J Orthop Surg Res. 2024 Jan 22;19(1):85. doi: 10.1186/s13018-024-04547-9. J Orthop Surg Res. 2024. PMID: 38254136 Free PMC article.
-
Unstable Thoracolumbar Injuries: Factors Affecting the Decision for Short-Segment vs Long-Segment Posterior Fixation.Int J Spine Surg. 2022 Aug;16(5):772-778. doi: 10.14444/8337. Epub 2022 Aug 17. Int J Spine Surg. 2022. PMID: 35977752 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials