Comparative Study
. 2016 Apr;254(4):797-808.
doi: 10.1007/s00417-015-3209-6. Epub 2015 Nov 4.

Inter-device size variation of small choroidal nevi measured using stereographic projection ultra-widefield imaging and optical coherence tomography

Affiliations
Comparative Study

Inter-device size variation of small choroidal nevi measured using stereographic projection ultra-widefield imaging and optical coherence tomography

Peter Maloca et al. Graefes Arch Clin Exp Ophthalmol. 2016 Apr.

Abstract

Purpose: Our purpose was to compare the tumor sizes of small choroidal nevi using ultra-widefield imaging (UWF) and different optical coherence tomography systems.

Methods: Thirteen choroidal nevi were measured using automatic and manual segmentation techniques, including enhanced depth imaging spectral-domain optical coherence tomography (EDI-SDOCT) and 1050 nm swept source OCT (SSOCT), to compare to measurements obtained using the Optos projection ultra-widefield fundus (UWF) imaging technique. Segmentation artifacts were evaluated for all 13 cases, alongside an additional 12 choroidal nevi, using SSOCT.

Results: In tumor eyes, segmentation artifacts for the choroid-sclera interface were found in 42 % of SSOCT scans. EDI-SDOCT can underestimate tumor dimensions and differs up to -8.41 % compared to UWF imaging and by 1.25 % compared to SSOCT cases. The horizontal length of the nevi showed an average difference between EDI-SDOCT and SSOCT of ± 9.38 %. Measured markers showed an average difference in length of ± 12.51 %. The average tumor thickness showed a difference of ± 11.47 %. Comparisons between EDI-SDOCT/UWF, SSOCT/EDI-SDOCT, and marker EDI-SDOCT/SSOCT showed significant mean differences of -122 μm (CI: -212 to -31 μm, p = 0.013), 134 μm (CI: 65-203 μm, p = 0.0012), and -193 μm (CI: -345 to -41 μm, p = 0.017), whereas SSOCT/UWF showed no significant difference with a measurement of 13 μm (CI: -69-95 μm, p = 0.74).

Conclusions: Automatic segmentation of nevi requires much caution, because a choroidal tumor can trigger many artifacts. It would be beneficial to monitor choroidal nevi using the same type of OCT technology, because a tumor is displayed differently.

Keywords: Choroid; Nevus; Optical coherence tomography; Widefield imaging.

PubMed Disclaimer

References

    1. Eye (Lond). 2013 Feb;27(2):243-52 - PubMed
    1. Indian J Ophthalmol. 2015 Feb;63(2):110-6 - PubMed
    1. Arch Ophthalmol. 1997 Dec;115(12):1537-44 - PubMed
    1. Ophthalmology. 2010 Jun;117(6):1177-1189.e4 - PubMed
    1. Br J Ophthalmol. 2015 Nov;99(11):1550-3 - PubMed

Publication types

LinkOut - more resources