A simple method for determining split renal function from dynamic (99m)Tc-MAG3 scintigraphic data
- PMID: 26537286
- DOI: 10.1007/s00259-015-3216-1
A simple method for determining split renal function from dynamic (99m)Tc-MAG3 scintigraphic data
Abstract
Purpose: Commonly used methods for determining split renal function (SRF) from dynamic scintigraphic data require extrarenal background subtraction and additional correction for intrarenal vascular activity. The use of these additional regions of interest (ROIs) can produce inaccurate results and be challenging, e.g. if the heart is out of the camera field of view. The purpose of this study was to evaluate a new method for determining SRF called the blood pool compensation (BPC) technique, which is simple to implement, does not require extrarenal background correction and intrinsically corrects for intrarenal vascular activity.
Methods: In the BPC method SRF is derived from a parametric plot of the curves generated by one blood-pool and two renal ROIs. Data from 107 patients who underwent (99m)Tc-MAG3 scintigraphy were used to determine SRF values. Values calculated using the BPC method were compared to those obtained with the integral (IN) and Patlak-Rutland (PR) techniques using Bland-Altman plotting and Passing-Bablok regression. The interobserver variability of the BPC technique was also assessed for two observers.
Results: The SRF values obtained with the BPC method did not differ significantly from those obtained with the PR method and showed no consistent bias, while SRF values obtained with the IN method showed significant differences with some bias in comparison to those obtained with either the PR or BPC method. No significant interobserver variability was found between two observers calculating SRF using the BPC method.
Conclusion: The BPC method requires only three ROIs to produce reliable estimates of SRF, was simple to implement, and in this study yielded statistically equivalent results to the PR method with appreciable interobserver agreement. As such, it adds a new reliable method for quality control of monitoring relative kidney function.
Keywords: 99mTc-MAG3 scintigraphy; Blood pool compensation; Kidney function; Radionuclide renography; Split renal function.
Comment in
-
Renal background correction and measurement of split renal function: The challenge : Editorial Comment: EJNM-D-15-00322, M Donald Blaufox, MD, PhD.Eur J Nucl Med Mol Imaging. 2016 Mar;43(3):548-9. doi: 10.1007/s00259-015-3253-9. Eur J Nucl Med Mol Imaging. 2016. PMID: 26572761 No abstract available.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous