Meta-Analysis
. 2016 Feb;58(2):171-7.
doi: 10.1007/s00234-015-1615-4. Epub 2015 Nov 9.

Delayed hemorrhagic complications after flow diversion for intracranial aneurysms: a literature overview

Affiliations
Meta-Analysis

Delayed hemorrhagic complications after flow diversion for intracranial aneurysms: a literature overview

Aymeric Rouchaud et al. Neuroradiology. 2016 Feb.

Abstract

Introduction: Delayed aneurysm rupture and delayed intraparenchymal hemorrhages (DIPH) are poorly understood and often fatal complications of flow diversion (FD) for intracranial aneurysms. The purpose of this study was to identify risk factors for these complications.

Methods: We performed a systematic review on post-FD delayed aneurysm rupture and DIPH. For each reported case, we collected the following information: aneurysm location, size and rupture status, type of flow diverter used, timing of the hemorrhage, and neurological outcome. We reported descriptive statistics of patients suffering DIPH and delayed aneurysm rupture to determine if there were any characteristics consistently present among patients with these complications.

Results: We identified 81 delayed aneurysm ruptures and 101 DIPH. Of the delayed ruptures, 76.6% (45/58) occurred within 1 month. The prognosis of delayed ruptures was poor, with 81.3% (61/75) experiencing death or poor neurological outcome. Giant aneurysms accounted for 46.3% of ruptures (31/67). Of these aneurysms, 80.9% (55/68) were initially unruptured. Of the delayed ruptured aneurysms, 17.8% (13/73) had prior or concomitant coiling. DIPHs were ipsilateral to the treated aneurysm in 82.2% (60/73) of cases. Of the DIPH, 86.0% (43/50) occurred within 1 month after FDS. Combined morbidity/mortality rate was 68.5% (50/73) following DIPH. Of DIPHs, 23.0% (14/61) occurred in patients with giant aneurysms.

Conclusions: Our study demonstrates that giant aneurysms represent almost 50% of delayed aneurysm ruptures in the flow diverter literature. About 2% of delayed ruptures occurred despite associated coiling. A substantial proportion of DIPHs occur early following FDS treatment of giant aneurysms.

Keywords: Complication; Delayed rupture; Flow diverter; Hemorrhage; Review.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Lylyk P, Miranda C, Ceratto R, Ferrario A, Scrivano E, Luna HR, Berez AL, Tran Q, Nelson PK, Fiorella D. Curative endovascular reconstruction of cerebral aneurysms with the pipeline embolization device: the Buenos Aires experience. Neurosurgery. 2009;64(4):632–642. doi: 10.1227/01.NEU.0000339109.98070.65. discussion 642-633; quiz N636. - DOI - PubMed
    1. Lubicz B, Collignon L, Raphaeli G, Pruvo JP, Bruneau M, De Witte O, Leclerc X. Flow-diverter stent for the endovascular treatment of intracranial aneurysms: a prospective study in 29 patients with 34 aneurysms. Stroke. 2010;41(10):2247–2253. doi: 10.1161/STROKEAHA.110.589911. STROKEAHA.110.589911 [pii] - DOI - PubMed
    1. Becske T, Kallmes DF, Saatci I, McDougall CG, Szikora I, Lanzino G, Moran CJ, Woo HH, Lopes DK, Berez AL, Cher DJ, Siddiqui AH, Levy EI, Albuquerque FC, Fiorella DJ, Berentei Z, Marosfoi M, Cekirge SH, Nelson PK. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial. Radiology. 2013;267(3):858–868. doi: 10.1148/radiol.13120099. - DOI - PubMed
    1. Brinjikji W, Murad MH, Lanzino G, Cloft HJ, Kallmes DF. Endovascular treatment of intracranial aneurysms with flow diverters: a meta-analysis. Stroke. 2013;44(2):442–447. doi: 10.1161/STROKEAHA.112.678151. - DOI - PubMed
    1. Arrese I, Sarabia R, Pintado R, Delgado-Rodriguez M. Flow-diverter devices for intracranial aneurysms: systematic review and meta-analysis. Neurosurgery. 2013;73(2):193–199. doi: 10.1227/01.neu.0000430297.17961.f1. discussion 199-200. - DOI - PubMed

Publication types

MeSH terms

LinkOut - more resources