Three-dimensional techniques and artificial intelligence in thallium-201 cardiac imaging
- PMID: 2655385
- DOI: 10.2214/ajr.152.6.1161
Three-dimensional techniques and artificial intelligence in thallium-201 cardiac imaging
Abstract
Three-dimensional reconstruction techniques including bull's-eye polar-coordinate maps, surface rendering, and surface modeling have been developed that help interpreting physicians assimilate complex 3-D tomographic data. Comparison of patient data with normal files highlights myocardial perfusion abnormalities, thus facilitating their recognition. In addition, AI systems that use heuristically defined rules derived from an expert knowledge base assist inexperienced observers in drawing conclusions regarding scan abnormalities.
Similar articles
-
[Three-dimensional display and its quantification of exercise stress myocardial tomography using thallium-201].J Cardiol. 1992;22(2-3):307-18. J Cardiol. 1992. PMID: 1339789 Japanese.
-
Reversibility bull's-eye: a new polar bull's-eye map to quantify reversibility of stress-induced SPECT thallium-201 myocardial perfusion defects.J Nucl Med. 1990 Jul;31(7):1240-6. J Nucl Med. 1990. PMID: 2362205
-
[Development and clinical application of an expert system for supporting diagnosis of 201Tl stress myocardial SPECT].Kaku Igaku. 1990 Feb;27(2):93-106. Kaku Igaku. 1990. PMID: 2348587 Japanese.
-
Single-photon perfusion imaging for the assessment of myocardial viability.J Nucl Med. 1994 Apr;35(4 Suppl):23S-31S. J Nucl Med. 1994. PMID: 8151409 Review.
-
Myocardial perfusion imaging using single-photon emission computed tomography.Am J Card Imaging. 1994 Apr;8(2):189-98. Am J Card Imaging. 1994. PMID: 8032191 Review.
Cited by
-
The use of computer-assisted diagnosis in cardiac perfusion nuclear medicine studies: a review (Part 3).J Digit Imaging. 1993 May;6(2):67-80. doi: 10.1007/BF03168433. J Digit Imaging. 1993. PMID: 8334175 Review.
-
The use of computer-assisted diagnosis in cardiac perfusion nuclear medicine studies: a review (Part 2).J Digit Imaging. 1993 Feb;6(1):1-15. doi: 10.1007/BF03168412. J Digit Imaging. 1993. PMID: 8439577 Review.
-
Quantification of SPECT myocardial perfusion images: methodology and validation of the Yale-CQ method.J Nucl Cardiol. 1999 Mar-Apr;6(2):190-204. doi: 10.1016/s1071-3581(99)90080-6. J Nucl Cardiol. 1999. PMID: 10327104
-
NMRES: an artificial intelligence expert system for quantification of cardiac metabolites from 31phosphorus nuclear magnetic resonance spectroscopy.Ann Biomed Eng. 1993 May-Jun;21(3):247-58. doi: 10.1007/BF02368180. Ann Biomed Eng. 1993. PMID: 8328724
-
Artificial intelligence in medicine and cardiac imaging: harnessing big data and advanced computing to provide personalized medical diagnosis and treatment.Curr Cardiol Rep. 2014 Jan;16(1):441. doi: 10.1007/s11886-013-0441-8. Curr Cardiol Rep. 2014. PMID: 24338557 Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources