. 1989 Jun;13(7):1561-71.
doi: 10.1016/0735-1097(89)90350-1.

Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function

Affiliations
Free article

Doppler color flow mapping in the evaluation of prosthetic mitral and aortic valve function

K K Kapur et al. J Am Coll Cardiol. 1989 Jun.
Free article

Abstract

Doppler color flow mapping and color-guided conventional Doppler studies were performed on 119 patients with 126 prosthetic valves (mitral alone in 60, aortic alone in 52 and both mitral and aortic in 7 patients) within 2 weeks of the catheterization study or surgery, or both. The mean pressure gradients derived by color-guided continuous wave Doppler ultrasound correlated well with those obtained at catheterization for both the tissue and mechanical mitral and aortic prostheses (r = 0.85 to 0.87). For the effective prosthetic orifice areas, better correlation with catheterization results were obtained with the tissue mitral (r = 0.94) and tissue aortic (r = 0.87) prostheses than with the mechanical mitral (r = 0.79) and mechanical aortic (r = 0.76) prostheses. The maximal width of the color flow signals at their origin from the tissue mitral prostheses also correlated well with the effective prosthetic orifice area at catheterization (r = 0.81). Doppler color flow mapping identified prosthetic valvular regurgitation with a sensitivity and specificity of 89% and 100%, respectively, for the mitral and 92% and 83% for the aortic prostheses. There was complete agreement between the Doppler color flow mapping and angiographic grading of the severity of prosthetic valvular regurgitation in 90% of mitral and 73.5% of the aortic regurgitant prostheses with under- or overestimation by greater than 1 grade in only two cases. Valvular and paravalvular regurgitation was correctly categorized by Doppler color flow mapping in relation to the surgical findings in 94% of the mitral and 80.5% of the aortic prostheses.